11
Cabling
Phillips quarter-turn screws and replace the four Phillips
screws on the back and the four Phillips screws on the
bottom.
8.
If you are using a Magix 400 E&M Tie Card, connect the
ground pin to the chassis ground screw as shown.
PIN NO.
6
3
1
4
5
2
1
2
3
4
5
6
7
8
PIN NO.
Male
Male
MVP 400/800
Connection
Magix 400 E&M 4
Wire Tire Card
M MOUTH CONTROL
E EAR CONTROL
T1 TIP 1 RECEIVE
R RING TRANSMIT
T TIP TRANSMIT
R1 RING 1 RECEIVE
CHASSIS GROUND SCREW
UNUSED
M I N P U T
E O U T P U T
T 1 4 - W I R E O U T P U T
R 4 - W I R E I N P U T , 2 - W I R E
T 4 - W I R E I N P U T , 2 - W I R E
R 1 4 - W I R E O U T P U T
S G ( S I G N A L G N D ) O U T P U T
S B ( S I G N A L B A T T E R Y O U T P U T
9.
Return to the Cabling Procedure.