MultiModemDSVD User Guide
28
W
Wait for a new dial tone before continuing to dial. (
X2
or
X4
must be selected.)
,
Pause during dialing for time set in register S8.
;
Return to command mode after dialing. (Place at end of
dial string.)
!
Hook flash. Causes the modem to go on-hook for the time
specified in S29, then off-hook again .
@
Wait for silence. Causes the modem to wait for 5 seconds of
silence before processing the next part of the command. If
silence is not detected within the time set in register S7, the
modem returns a NO ANSWER or BUSY code.
^
Toggle data calling tone on or off. Applies only to current
dialing attempt.
$
Detect credit card “bong” tone. If the tone is not detected
within the time specified by S7 (US models), the modem
aborts the rest of the sequence and hangs up. The character
should follow the phone number and precede the user’s
call card number, e.g.,
ATDT1028806127853500$123456789
.
Command:
DS=
y Dial Stored Telephone Number
Values:
y
= 0–3
Default:
none
Description:
Dial a number previously stored in directory
y
by the
&Zy=x
command. Example:
ATDS=3
dials the number in directory 3.
Command:
E
n
Echo Command Mode Characters
Values:
n
= 0 or 1
Default:
1
Description:
E0
Do not echo keyboard input to the terminal.
E1
Do echo keyboard input to the terminal.
Command:
H
n
Hook Control
Values:
n
= 0 or 1
Default:
0
Description:
H0
Go on-hook (hang up) and terminate any
&T
test that is in
progress.
H1
Go off-hook (make the phone line busy) and enter command
mode.
Command:
I
n
Information Request
Values:
n
= 0–6
Default:
None
Description:
I0
Display the product code. Example: 33600.
I1
Calculate the ROM checksum and display the least significant
byte in decimal format.
I2
Calculate the ROM checksum and compare it to the prestored
checksum, displaying
OK
if they match, or
ERROR
if they do not.
I3
Display the controller firmware version (F), the basic model
(V90), the application code (A), and the interface type code (I) in
the format VF.FFF-V90_AI. The application codes are
D
for desk-
top and
L
for low power (PCMCIA). The interface codes are
S
for serial and
P
for parallel. Example:
V2.210-V90_2M_DLS.
Содержание MT5600DSVD2
Страница 1: ......
Страница 3: ...iii...
Страница 8: ...MultiModemDSVD User Guide viii...
Страница 9: ...1 Introduction...
Страница 13: ...2 Quick Start...
Страница 26: ...MultiModemDSVD User Guide 18...
Страница 27: ...3 Features...
Страница 33: ...4 AT Commands S Registers Result Codes...
Страница 59: ...5 Solving Problems...
Страница 66: ...MultiModemDSVD User Guide 58...
Страница 67: ...Appendixes...
Страница 72: ...MultiModemDSVD User Guide 64...
Страница 76: ...MultiModemDSVD User Guide 68...
Страница 90: ...MultiModemDSVD User Guide 82...
Страница 91: ...Index...