![Multitech MT4X56 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/multitech/mt4x56/mt4x56_user-manual_1855892050.webp)
MultiModemUSB User Guide
MT4X56USB
50
S38
decimal
0–23
1
Sets “downstream” data rate where K56flex provides rates
of 32,000 to 56,000 in 2,000 bps increments, V.90 provides
rates of 28,000 to 56,000 bps in increments of 1,333 bps.
0 = V.90 disabled
1 = V.90 autorate
K56flex rates
2 = 28,000 bps
2 = 32,000 bps
3 = 29,333 bps
3 = 34,000 bps
4 = 30,666 bps
4 = 36,000 bps
5 = 32,000 bps
5 = 38,000 bps
6 = 33,333 bps
6 = 40,000 bps
7 = 34,666 bps
7 = 42,000 bps
8 = 36,000 bps
8 = 44,000 bps
9 = 37,333 bps
9 = 46,000 bps
10 = 38,666 bps
10 = 48,000 bps
11 = 40,000 bps
11 = 50,000 bps
12 = 41,333 bps
12 = 52,000 bps
13 = 42,666 bps
13 = 54,000 bps
14 = 44,000 bps
14 = 56,000 bps
15 = 45,333 bps
16 = 46,666 bps
17 = 48,000 bps
18 = 49,333 bps
19 = 50,666 bps
20 = 52,000 bps
21 = 53,333 bps
22 = 54,666 bps
23 = 56,000 bps
Upstream data rates
Upstream V.90 data rates are 4800 to 33,600 bps in 2400
bps increments.
S42
decimal
0–1
1
Enables/disables the 56K auto rate. When 56K auto is
disabled, fallback to V.34 is also disabled. 0 = disable;
1 = enable.
S43
decimal
0–1
1
For For testing and debugging only. Enables/disables
V.32bis start-up auto mode operation. 0 = disable; 1 =
enable.
S48
decimal
7 or 128
7
Enables (7) or disables (128) LAPM negotiation. The follow-
ing table lists the S36 and S48 configuration settings for
certain types of connections.
S48=7
S48=128
LAPM or async
Async
LAPM or hangup
Do not use
LAPM, MNP, or aysnc
LAPM, MNP, or hangup
MNP or hangup
MNP or async
S36=0, 2
S36=1, 3
S36=4, 6
S36=5, 7
S89
seconds
0, 5–255
10
Sets the length of time in the off-line command mode before
the modem goes into standby mode. A value of zero
prevents standby mode; a value of 1–4 sets the value to 5.
S108
decimal
0–3, 6, 7
6
Selects the 56K digital loss if using the modem thru a PBX
line. The default value is -6 dB loss, the value used when
calling from a typical POTS line long distance.
0 = -0 dB digital loss, no robbed-bit signaling
1 = -3 dB PBX digital loss
2 = -2 dB digital loss
3 = -3 dB digital loss
6 = -6 dB digital loss
7 = -0 dB digital loss with robbed-bit signaling
S109
decimal
0--2
1
Sets one of three 56K operating modes:
K56flex mode, V.90 mode, or Auto-mode.
S109=2 forces V.90 connections for testing purposes, etc. S109
sets the 56K operating mode as shown below:
0 = V.90 disabled
1 = K56flex or V.90 (Dual mode enabled)
2 = V.90 only (K56flex disabled).
Содержание MT4X56
Страница 1: ...Four USB V 90 Modems MultiModemUSB Model MT4X56USB User Guide...
Страница 5: ...Four USB V 90 Modems Chapter 1 Introduction and Description...
Страница 11: ...Four USB V 90 Modems Chapter 2 Installation...
Страница 14: ...MultiModemUSB User Guide MT4X56USB 14...
Страница 15: ...Four USB V 90 Modems Chapter 3 Software Loading and Configuration...
Страница 38: ...MultiModemUSB User Guide MT4X56USB 38...
Страница 39: ...Four USB V 90 Modems Chapter 4 AT Commands S Registers and Result Codes...
Страница 53: ...Four USB V 90 Modems Chapter 5 Remote Configuration...
Страница 56: ...MultiModemUSB User Guide MT4X56USB 56...
Страница 57: ...Four USB V 90 Modems Chapter 6 Troubleshooting...
Страница 65: ...Four USB V 90 Modems Chapter 7 Upgrade Procedure...
Страница 69: ...Four USB V 90 Modems Chapter 8 Service Warranty and Tech Support...
Страница 73: ...Four USB V 90 Modems Appendices...
Страница 79: ...Four USB V 90 Modems Glossary of Terms...