background image

FACTORY SETTING

PARAMETER

IT

CT

Offset

PB

DT

MR

Hysteresis

VALUES

300

15 Sec 

20.0°C

75

0°C

0°C

3°C

SR.

2

4

6

1

3

5

7

ERROR

OPEN

SRE

MEANING

When an error has occurred the display indicates error codes
 as given below.   

Sensor is not connected or  
Over range condition or 
sensor break

Sensor connection is reversed

ERROR DISPLAY

FACTORY SETTING

Press      +      key
for 3 sec 

CORRECTIVE ACTION:

Check the sensor and the input wiring. If problem still exists, 
replace the sensor. And still if problem is not solved yet by the
user, then please contact company person

yes

         : Press        key to apply factory set 
           values as shown in table.

         : Press       key to exit
           from factory setting.

ENT

ENT

  35

SET

100

Process Value

Set Point

no

SET

Press         key

 34

 FCST

 YES

 NO

pass

Password Message

50

ENT

Press      k

e

y

SET

SET

SET

SET

Press      key for 5 sec

Delay Time

6 Sec

8

SET POINT SETTING

Page 4

 Specifications are subject to change, since development is a continuous process, 

So for more updated operating information and Support, 

Please contact our Helpline: 9978991476/9978991474/9978991482 or 

Email at 

 Ver:200201

[email protected]

CONTROL FUNCTION

RLY-OFF

RLY-ON

RLY-ON

RLY-ON

RLY-OFF

RLY-OFF

Tem

p.

S.V

HYST

Time

ON - OFF control (Heating)

OFF 

OFF 

ON  

ON  

delay

delay

delay

Time

Time

Time

RLY-ON

RLY-OFF

Tem

p.

HYST

S.V

Time

OFF 

OFF 

OFF 

ON - OFF control (Cooling)

ON  

ON  

ON  

PID AUTO-TUNING

Press      key for 6 sec to start/stop

PID auto-tuning 

Auto Tuning:-

The Auto-tuning function automatically computes 
and sets the Proportional band (Pb) , Integral time (It), 
Derivative time (dt), and cycle time as per process 
characteristics. 

Tuning LED will turn “ON” during Auto-Tuning

If the power goes off before auto-tuning is completed,
 auto-tuning will be restarted at next power ON.

Содержание UTC-114

Страница 1: ...uto Tuning 3 ON OFF control 96 H x 96 W x 52 D mm 100 to 270V AC 50 60Hz 0 C to 55 C UP to 95 RH non condensing IP 65 Front side As per IS IEC 60529 2001 1 Nos 12V DC 30mA DC On Off condition 1C O NO C NC 10A 230V AC 28V DC Reg Load SET INC DEC ENT ON OFF control 92 H x 92 W mm 4VA 230V AC MAX Relay Output SSR Drive Output TECHNICAL SPECIFICATION MECHANICAL INSTALLATION TERMINAL CONNECTION Outline...

Страница 2: ... expected by using standard power supply cable for the instrument Ω INSTALLATION GUIDELINES 1 This equipment being built in type normally becomes a part of main control panel and in such case the terminals do not remain accessible to the end user after installation and internal wiring 2 Do not allow pieces of metal wire clippings or fine metallic fillings from installation to enter the product or ...

Страница 3: ... SET Press key SET Press key SET SET Press key Press key ENT Press key to save exit DT 75 CT 15 MR 0 pB 20 0 IT 300 ENT Press key to save exit MR pb2 5 CT2 8 0 Proportional Band IF PID Action Selected IP TP Action Selected Integral Time Derivative Time Cycle Timer Manual Reset Proportional Band Cycle Timer Manual Reset SET Press key SET Press key SET Press key PB IT DT CT MR OffSet Hysteresis Dela...

Страница 4: ...Press key SET SET SET SET Press key for 5 sec Delay Time 6 Sec 8 SET POINT SETTING Page 4 Specifications are subject to change since development is a continuous process So for more updated operating information and Support Please contact our Helpline 9978991476 9978991474 9978991482 or Email at Ver 200201 service multispanindia com CONTROL FUNCTION RLY OFF RLY ON RLY ON RLY ON RLY OFF RLY OFF Temp...

Отзывы: