DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #0 (02/04/14) — PAGE 51
1
DCA-220SSJ/SSJU — SETUP
When connecting battery do the following:
1.
NEVER
connect the battery cables to the battery
terminals when the
MPEC Control Switch
is in either
the
MANUAL
or
AUTO
position.
ALWAYS
make sure that
the
MPEC Control Switch
is in the
OFF/RESET
position
when connecting the battery.
2. Place a small amount of battery terminal treatment
compound around both battery terminals. This will ensure
a good connection and will help prevent corrosion around
the battery terminals.
Figure 37. Battery Connections
ALWAYS
disconnect the negative terminal
FIRST
and
reconnect negative terminal
LAST
.
Inadequate battery connections may cause poor starting
of the generator, and create other malfunctions.
Alternator
The polarity of the alternator is negative grounding type. When
an inverted circuit connection takes place, the circuit will be
in short circuit instantaneously resulting the alternator failure.
DO NOT
put water directly on the alternator. Entry of water
into the alternator can cause corrision and damage the
alternator.
Wiring
Inspect the entire generator for bad or worn electrical wiring
or connections. If any wiring or connections are exposed
(insulation missing) replace wiring immediately.
Piping and Hose Connection
Inspect all piping, oil hose, and fuel hose connections for
wear and tightness. Tighten all hose clamps and check hoses
for leaks.
If any hose (
fuel
or
oil
) lines are defective replace them
immediately.
Battery
This unit is of negative ground
DO NOT
connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level are not
properly maintained. Add only distilled water when
replenishment is necessary.
DO NOT
over fill. Check to see whether the battery cables
are loose. Poor contact may result in poor starting or
malfunctions.
Always
keep the terminals firmly tightened.
Coating the terminals with an approved battery terminal
treatment compound. Replace battery with only
recommended type battery.
The battery is sufficiently charged if the specific gravity of
the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Before charging the battery with an external electric source,
be sure to disconnect the battery cables.
Battery Cable Installation
ALWAYS
be sure the battery cables (Figure 37) are properly
connected to the battery terminals as shown below. The
Red
Cable
is connected to the positive terminal of the battery,
and the
Black Cable
is connected to the negative terminal
of the battery.
CAUTION - BATTERY SERVICING SAFETY
CAUTION - BATTERY SERVICING SAFETY
If the battery cable is connected incorrectly, electrical
damage to the generator will occur. Pay close attention to
the polarity of the battery when connecting the battery.
NOTICE
Содержание Power WHISPERWATT DCA-220SSJ
Страница 3: ...DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 PAGE 3 1 DCA 220SSJ SSJU NOTE PAGE...
Страница 69: ...DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 PAGE 69 1 NOTE PAGE...
Страница 72: ...PAGE 72 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU GENERATOR ASSY...
Страница 74: ...PAGE 74 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU GENERATOR ASSY CONT...
Страница 76: ...PAGE 76 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU CONTROL PANEL ASSY...
Страница 78: ...PAGE 78 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU CONTROL BOX ASSY...
Страница 80: ...PAGE 80 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU CONTROL BOX ASSY CONT...
Страница 82: ...PAGE 82 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU ENGINE AND RADIATOR ASSY...
Страница 84: ...PAGE 84 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU ENGINE AND RADIATOR ASSY...
Страница 86: ...PAGE 86 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU ENGINE AND RADIATOR ASSY...
Страница 88: ...PAGE 88 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU OUTPUTTERMINAL ASSY...
Страница 90: ...PAGE 90 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU OUTPUTTERMINAL ASSY CONT...
Страница 92: ...PAGE 92 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU BATTERY ASSY...
Страница 94: ...PAGE 94 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU MUFFLER ASSY...
Страница 96: ...PAGE 96 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU FUELTANK ASSY...
Страница 98: ...PAGE 98 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU ENCLOSURE ASSY...
Страница 100: ...PAGE 100 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU ENCLOSURE ASSY CONT...
Страница 102: ...PAGE 102 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU ENCLOSURE ASSY CONT...
Страница 104: ...PAGE 104 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU ENCLOSURE ASSY CONT...
Страница 106: ...PAGE 106 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU RUBBER SEALS ASSY...
Страница 108: ...PAGE 108 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU NAMEPLATE AND DECALS ASSY...
Страница 110: ...PAGE 110 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU NAMEPLATE AND DECALS ASSY CONT...
Страница 113: ...DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 PAGE 113 1 NOTE PAGE...