PAGE 38 — DCA-600SSV — OPERATION AND PARTS MANUAL — REV. #0 (07/13/09)
DCA-600SSV— SETUP
When connecting battery do the following:
1.
NEVER
connect the battery cables to the battery
terminals when the
ignition
switch is in either the
Pre-
Heat, RUN, or START
position.
ALWAYS
make sure
that the ignition switch is in the
STOP
position when
connecting the battery.
2. Place a small amount of battery terminal treatment
compound around both battery terminals. This will ensure
a good connection and will help prevent corrosion around
the battery terminals.
Figure 39. Battery Connections
Alternator
The polarity of the alternator is negative grounding type.
When an inverted circuit connection takes place, the circuit
will be in short circuit instantaneously resulting the alternator
failure.
DO NOT
put water directly on the alternator. Entry of water
into the alternator leads an electrolyte corrosion causing an
alternator failure.
Before charging the battery with an external electric source,
be sure to disconnect the battery cables.
Wiring
Inspect the entire generator for bad or worn electrical wiring
or connections. If any wiring or connections are exposed
(insulation missing) replace wiring immediately.
Piping and Hose Connection
Inspect all piping, oil hose, and fuel hose connections for
wear and tightness. Tighten all hose clamps and check hoses
for leaks.
If any hose (
fuel
or
oil
) lines are defective replace them
immediately
.
If the battery cable is connected
incorrectly, electrical damage to the
generator will occur. Pay close
attention to the polarity of the
battery when connecting the
battery.
NOTE
Battery
This unit is of negative ground
DO NOT
connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level are
not properly maintained. Add only distilled water when
replenishment is necessary.
DO NOT
over fill. Check to see whether the battery cables
are loose. Poor contact may result in poor starting or
malfunctions.
Always
keep the terminals firmly tightened.
Coating the terminals with an approved battery terminal
treatment compound. Replace battery with only
recommended type battery.
The battery is sufficiently charged if the specific gravity of
the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Battery Cable Installation
ALWAYS
be sure the battery cables (Figure 39) are properly
connected to the battery terminals as shown below. The
RED
cable is connected to the positive terminal of the battery,
and the
BLACK
cable is connected to the negative terminal
of the battery.
CAUTION - BATTERY SERVICING SAFETY
ALWAYS
disconnect the negative terminal
FIRST
and
reconnect negative terminal
LAST
.
Inadequate battery connections may cause poor starting
of the generator, and create other malfunctions.
CAUTION - BATTERY SERVICING SAFETY
Содержание DCA-600SSV
Страница 61: ...DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 PAGE 61 NOTE PAGE...
Страница 64: ...PAGE 64 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 GENERATOR ASSY DCA 600SSV GENERATOR ASSY...
Страница 66: ...PAGE 66 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV GENERATOR ASSY CONT GENERATOR ASSY...
Страница 68: ...PAGE 68 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV CONTROL BOX ASSY CONTROL BOX ASSY...
Страница 70: ...PAGE 70 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV CONTROL BOX ASSY CONT CONTROL BOX ASSY...
Страница 72: ...PAGE 72 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV CONTROL BOX ASSY CONT CONTROL BOX ASSY...
Страница 84: ...PAGE 84 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV BATTERY ASSY BATTERY ASSY...
Страница 86: ...PAGE 86 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV MUFFLER ASSY MUFFLER ASSY...
Страница 88: ...PAGE 88 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV FUELTANK ASSY FUEL TANK ASSY...
Страница 90: ...PAGE 90 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV ENCLOSURE 1 ASSY ENCLOSURE 1 ASSY...
Страница 92: ...PAGE 92 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV ENCLOSURE 1 ASSY CONT ENCLOSURE 1 ASSY...
Страница 94: ...PAGE 94 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV ENCLOSURE 2 ASSY ENCLOSURE 2 ASSY...
Страница 96: ...PAGE 96 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV ENCLOSURE 2 ASSY CONT ENCLOSURE 2 ASSY...
Страница 98: ...PAGE 98 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV ENCLOSURE 3 ASSY ENCLOSURE 3 ASSY...
Страница 100: ...PAGE 100 DCA 600SSV OPERATION AND PARTS MANUAL REV 0 07 13 09 DCA 600SSV RUBBER SEAL ASSY RUBBER SEAL ASSY...