Configuration Commands:
The configuration settings are loaded from user non-volatile memory on powerup. If the user
non-volatile memory is corrupt, the settings will be loaded from the factory defaults.
mfas
Description:
Saves all of the current working configuration settings into user non-
volatile memory.
Command:
mfas<CR>
Response:
m<CR>
Configuration saved
F<CR>
Failed
?<CR>
Syntax failure
mfal
Description:
Loads the user non-volatile configuration settings into current working
memory.
Command:
mfal<CR>
Response:
m<CR>
Configuration loaded
F<CR>
Failed
?<CR>
Syntax failure
mfad
Description:
Loads the factory default configuration settings into current working
memory.
Command:
mfad<CR>
Response:
m<CR>
Defaults loaded
F<CR>
Failed
?<CR>
Syntax failure
BAUD
Description:
Changes the current baud rate of the host communications serial port.
The command will respond in the previous baud rate and then the host
should immediately change its baud rate. After two seconds from the
time the command was sent, the controller will be ready to accept
commands at the new baud rate. The available rates are 9600, 19200,
38400, 57600, and 115200.
Command:
BAUD<u32><CR>
Response:
B<CR>
Baud rate changed
F<CR>
Failed (Baud rate not changed)
?<CR>
Syntax failure