3. General Warnings

3.1 Laser Light Warning

Never look directly into the end of a fiber that may be carrying laser light. Laser light 

can be invisible and may be harmful to your eyes. Viewing it directly may not cause pain; 

therefore it will not cause blinking or the iris of the eye to close involuntarily as it does when 

viewing bright light. Consequently, serious damage to the retina of the eye is possible. Should 

accidental exposure of laser light be suspected, arrange an eye exam immediately.

3.2 Laser Light Magnification Warning

Do not use magnifiers in the presence of laser radiation. Diffused laser light can cause 

serious eye damage if focused with optical instruments. 

3.3 Loose Fiber Warning

Cleaved or broken glass fibers are very sharp and can pierce the skin easily. Keep your 

work area clear of removed fiber. Do not allow pieces of fiber to stick to your clothing or fall 

into the work area where they can cause injury later. Use tweezers to pick up broken/cut 

pieces of fiber and place on a piece of tape that has been set aside for this purpose.

3.4 Sharp Edge Warning

The wearing of cut-resistant safety gloves to protect your hands from sharp cutting 

tools and the metal armoring of armored cable is strongly recommended. Use extreme care 

when working with severed armor. There may be sharp edges where the armor is damaged. 

Always cover the exposed/cut armor end with a wrap of black electrical tape. To minimize the 

chance of injury from sharp-blade tools, always cut away from yourself and others. Dispose of 

used blades and armor scrap properly.

3.5 Safety Glasses Warning

Use safety glasses while working is highly recommended to provide eye protection 

from accidental injury when handling chemicals, cables or working with fiber. Pieces of glass 

fiber are very sharp and have potential to damage the eye.

3.6 Electrical Shock Warning

Do not install telecommunications equipment or work with telephone wiring during 

a lightning storm. Telephone lines can carry high voltages from lightning causing electrical 

shock resulting in severe injury or death.

3.7 Fiber Damage Warning

Fiber Optic cable is highly sensitive to excessive pulling, bending and crushing. Take 

care when bending the cables. Be sure not to pull too hard on the fibers. Do not crush the 

cable or allow it to kink. Doing any of these things may cause damage to the fiber and require 

it to be replaced.

Содержание Optima 16

Страница 1: ...uide Optima 16 Enclosure General 3 1 Introduction 3 1 1 Product Description 1 2 Optima 16 Dimensional Drawing 2 Preparations 4 2 1 Installation Outline 2 2 Optima 16 Checklist 2 3 Recommended Tools an...

Страница 2: ...12 Proper Grommet Seal 4 13 Install CSM Cable Grommet 4 14 Secure Cable to Base 4 15 Fiber Routing Attach Tie Wraps 4 16 Buffer Tube Branching 4 17 Attach Tie Wraps Splicing Buffer Tube to Pigtail 10...

Страница 3: ...lateral cable to be connected to single drop cable at another location This guide is for installers who are familiar with fiber optic cable systems and their applications 1 1 Product Description Mult...

Страница 4: ...Member Ring cut fiber separation CSM tie down and routing fiber Securing fiber in place to the Optima 16 closure Configuring grommets for cable entry and exit drop Splicing and fiber termination 2 2...

Страница 5: ...s of fiber and place on a piece of tape that has been set aside for this purpose 3 4 Sharp Edge Warning The wearing of cut resistant safety gloves to protect your hands from sharp cutting tools and th...

Страница 6: ...VIEW CN 01 SEE B O M N A CN 04 27 15 01 N A INITIAL RELEASE Figure 4 1A 4 3 Cut Trim CSM Measure 2 inches from each side of the ring cut locations with the exposed buffer tubes and make a mark on eac...

Страница 7: ...on opposite side of ring cut 4 4 Armored Cable Allow at least 1 of the cable s armor to remain from the jacketing Slowly peel back the armor using pliers to separate the seam to allow the wedge from...

Страница 8: ...outside of the enclosure to ensure a water tight seal With the long threaded end on the inside of the enclosure attach the ground lug to the base by using the supplied washer and nut s 4 10 Install CS...

Страница 9: ...d tie wraps insert into each fiber management clip on the lower side of the base and tighten down enough to hold in place but not directly damage the fiber 4 13 Install CSM Cable Grommet Place the fib...

Страница 10: ...o secure your spliced fibers 4 19 Splice Tray Routing Place the completed splice tray within the Optima 16 base Route the branched off buffer tube s accordingly along with how the pigtail slack will b...

Страница 11: ...lied tie wraps insert into each fiber management clip on the shell to hold the fiber pigtail 4 21 Attach Splice Tray Cover Before finalizing the splicing section of the Optima 16 attach the splice tra...

Страница 12: ...ns Prior to isntallation use sealant to lubricate the outer edge of the grommet for a proper seal In this case we will use blank grommets to seal up the opening Ensure the grommets are inserted into t...

Страница 13: ...fiber pigtail is held in place so that the buffer tubes do not get pinched in closing 4 29 Apply Sealant to the Perimeter Before completely shutting the closure flush apply the supplied sealant to the...

Страница 14: ...ctions need to be inserted into the supplied foam parking lot 4 33 Latch Cover to Optima Shell Once the sealant has been applied to the gel then close the Optima 16 cover using the plastic latch locat...

Страница 15: ...ters additional accessories some of which are included with the Optima S and patch splice options including installable kits and pigtails Mounting Kits Products Description Stock ID Standard Tap Brack...

Страница 16: ...0 2019 Page 16 Document No Optima 16 Installation Guide Accessory List Cont Splice Tray Products Description Stock ID 1124 SSTP 072 059 20 Drop Cable Products Description Stock ID OptiDrop Custom Conn...

Страница 17: ...NS Copyright 2019 Multilink Inc All rights reserved Specifications subject to change without notice Rev 11 20 2019 Multilink Inc 2019 All Rights Reserved www gomultilink com P R O U D L Y MANUFACTURED...

Отзывы: