background image

 

AT4039EML 

|

User Manual 

12

|

P a g e

 

C

O

MMU

N

IC

A

T

IO

N

 T

E

ST

 &

 ME

A

SU

R

EME

N

SO

LU

TI

O

N

Installation 

This chapter covers installation of the instrument, addressing the following topics: 

 

System Start-up 

 

How to connect to the instrument 

 

First Steps 

 

When you first receive the instrument, it has a pre-configured IP address from the 
factory. This IP address is printed on a label on the instrument. You may choose to 
keep this IP or to change it. If you need to change the IP, there are two ways to do 
so: either through the USB  interface, or through the Ethernet interface. If you do 
choose USB,  then you first have to install the USB  driver of this instrument from 
the ML website, then use the application named ETHconfig. If however you choose 
the LAN interface to  change the IP, then you need to  download the application 
IPChanger from the ML  website then temporarily change your PC’s IP to be in the 
same  domain  as  the  instrument,  i.e.  172.16.xx.xx.  once  you’ve  successfully 
changed the instrument’s IP, you can change back your PC’s IP. 

 

Please make sure you print a label with the newly assigned IP address and stick it 
on the instrument. If for some reason you cannot remember what IP address your 
instrument has, you will have to use the USB interface together with the ETHconfig 
software to “read” the IP. 
 

Connect through Ethernet

:  

Connect the PC to the front panel via the RJ45  connector located on the front 
panel through an Ethernet cable to be able to control it. 
In order to connect via Ethernet, the IP address of the board is required. 
To learn more options on how to connect the Ethernet cable go to the section 

Connect through an Ethernet Cable

. 

o

 

Note that  no  drivers are  required; you simply should know  the  current 
board IP address, you need to enter it in the text box next to the 

IP

 label 

shown in the below picture, then click on the 

connect

 button.  

 

 

Figure 7: 

Connect Via Ethernet

 

 

o

 

You are now connected. 

o

 

Once connected, the 

Connect

 button turns into 

Disconnect

o

 

To make sure that you are connected, you can also ping your device. 

o

 

To change the IP address of the board, you need to install  the USB drivers 
(refer to sectio

USB Driver Installation

). 

o

 

Install the Ethernet configuration software that allows you to read, write 
the 

IP 

address, 

Mask

 and 

Gateway

 of the instrument. 

Содержание AT4039EML

Страница 1: ...AT4039EML 4 Lane 23 29 46 58 GBaud Bit Error Ratio Tester 400G NRZ PAM4 AT4039EML BERT User Guide www multilaneinc com...

Страница 2: ...of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 or subparagraphs c 1 and 2 of the Commercial Computer Software RestrictedRights clause at FAR 52 227 19 as applicabl...

Страница 3: ...alled Firmware Revision 14 Line Rate Configuration Applies to all channels at once 14 Mode Clock Out Settings Apply to all channels at once 15 Per Channel Settings 16 Taking Measurements 20 Bit Error...

Страница 4: ...igure 9 Ethernet Configuration 13 Figure 10 AT4039EML GUI 13 Figure 11 Default Inner and Outer settings of 1000 and 2000 20 Figure 12 Outer Eye is set 1600 Inner eye kept at 2000 20 Figure 13 BER Cont...

Страница 5: ...ratings information before making connectionsto the product Do not applya potential toany terminal includingthe commonterminal thatexceedsthe maximumrating of that terminal Do Not Operate Without Cove...

Страница 6: ...t covers the followinginformation Describes the capabilities of the instrument how to install it and its software packages Explainshow to operate the instrumentfor Pattern Generation Error Detection h...

Страница 7: ...s advanceddevelopmentand test tools MultiLane has the resources andknow how to meet customer s product development and design requirements Our R D has a proven track record in delivering leading edge...

Страница 8: ...ATE The ATE versioniscalledAT4039EML and iscompatible withthe AdvantestV93000 HSIOtest head extenderframe twinning Hardware Packages AT4039EML 4 x 28G NRZ PAM4 and 4 x 56G NRZ PAM4 Channels BERT in a...

Страница 9: ...AT4039EML User Manual 5 P a g e COMMUNICATION TEST MEASUREMENT SOLUTIONS Figure 2 The buildingblocksofthe test head extender FamilyBoard Base Frame Pogo Segment DUT Load board...

Страница 10: ...AT4039EML User Manual 6 P a g e COMMUNICATION TEST MEASUREMENT SOLUTIONS Figure 3 V93Kframewith 4 Multilanecassettesinstalled Figure 4 ComponentsoftheMultilanesub systeminside theV93Kframe...

Страница 11: ...connectors are labeled U450 U451 U452 and U453 4 Power connector Each backplane has a 12V 13A powerconnector 5 Clock out Clock out from a BERT is available as a differential pairat the indicated SMP 6...

Страница 12: ...ting of the channels is simultaneousinone move Alsothe bandwidthof the coaxial assemblyis 50 GHz All APIs are available for Linux and testedunder SmarTest 7 For the listof APIs and how to use them ple...

Страница 13: ...ML4039EML AT4039EML WindowsGUI USB driver Overview AT4039EML is a low cost simple to use fully integrated ultra compact USB Fast Ethernet controlled instrument that combines the functions and features...

Страница 14: ...r ML IPChanger InstrumentGUI runs on Windows XP 32 64 bit Windows7 8 and 10 NOTE These applications require the Microsoft NET Framework 3 5 If the Microsoft NET Framework 3 5 is needed it can be downl...

Страница 15: ...cations Windows7 or greater Minimum 1 GB RAM 1 Ethernet card to establishconnectionwiththe device USB Connector Pentium4 processor 2 0 GHz or greater NET Framework 3 5 sp1 NOTE It is recommended to co...

Страница 16: ...ou print a label withthe newlyassignedIP address and stick it on the instrument If for some reason youcannot rememberwhatIP addressyour instrumenthas youwill have touse the USBinterface togetherwithth...

Страница 17: ...ONS Figure 8 EthernetConfiguration The instrumentisnowpoweredupand connectedthrough the right IPaddress Next you needto configure the signal generated GUI Overview Figure 9 AT4039EMLGUI In your instru...

Страница 18: ...rrect polarity and PRBS kindis detectedon the error detector If the temperature reaches 65C the electronicswill autoshut off Reading the installed Firmware Revision The installedfirmware versionisdisp...

Страница 19: ...pes require a clock frequency above 2 GHz To get the AT4039EML to output that go under mode settings and select the Clock out to be Monitor Choose the denominator so that the result is within the scop...

Страница 20: ...10 3 Per ChannelSettings You can adjust these settingson a per channel basis These are The AT4039EML can output a wide range of pre defined patterns In addition to the PRBS patterns there are lineari...

Страница 21: ...M levels are denoted 0 1 2 and 3 Example 2 to transmit a stair signal 0123 fill out the fields with repetitions of 1E In the RX Pattern menu one can browse all the patterns with which error detection...

Страница 22: ...e default amplitude control is calibrated in millivolt values but does not allow you to change the equalizer settings If you need to change the FFE tap settings please go to then enable Advanced Setti...

Страница 23: ...lease ensure that the sum of pre post and main cursors is 1000 to have optimal performance If the sum of taps exceeds 1000 linearity of the TX signal cannot be maintained Pre cursor effect on a pulse...

Страница 24: ...urements the instrument ports should be in the loopback mode which meansTX port shouldbe connectedto the RX port usinga balloon and the PPG and ED patterns shouldmatch One doesnot necessarilyneedtosup...

Страница 25: ...stop until the user intervenesandclicks the stop button BER can also be set to run unit a target value is reached or until a certain number of bitshas been transmitted unitsof 10 gigabits The Timer le...

Страница 26: ...shootthe link You can thinkof it as a scope builtinto the receiverand it works evenif you do not have pattern lock For both NRZ and PAMsignals the histogram graph is shown as follows Figure 14 PAMHist...

Страница 27: ...sure the strengthof the received signal itis givenin dB Figure 16 SNRratio for PAMsignal Log file System In the AT4039EML BERT there isa log file system where everyexceptionhandledor unhandledby the G...

Страница 28: ...weekof work Saving and LoadingSettings The instrumentalways savesthe last usedsettingsin non volatile memory These settingsare automatically restoredthe nexttime you connect to the BERT In addition yo...

Страница 29: ...IP Address and Update Firmware The AT4039EML has two PC interfaces USB and Ethernet The USB interface isonly for changing the IP address of the instrumentand for updatingfirmware One cannot interact...

Страница 30: ...Maintenance nextto the USB radio button selection 3 Connect to your instrumentusing the USB option 4 Clickon IP Configuration to substitute the oldIP with the newdesiredone 5 Powercycle the instrumen...

Страница 31: ...2 168 1 5 see Figure 19 6 Clickon Connect then Load Hex File 7 Clickon Erase Program Verify and waittill it displaysupdate success then click Run Application 8 Powercycle the instrument Figure 19 Firm...

Страница 32: ...e into the PC and connect it to the panel Make sure the PC can locate and install the driver If thisdoes not happen automatically you will needto give Windowsthe path to the driver sfolder USB Driver...

Страница 33: ...earch for the driversoftware Select Browse my computer for driver software A dialogbox appears asking for the Driversoftware path Enter the path and click Next A security dialogbox appears select Inst...

Страница 34: ...AT4039EML User Manual 30 P a g e COMMUNICATION TEST MEASUREMENT SOLUTIONS...

Отзывы: