Warning: 

To prevent electric shock or fire, use a suitable power adapter. Only power 

adapters that are dedicated to this product and approved for use in the country 

of use may be used. 

Warning: 

The two channels of the oscilloscope are non-isolated channels. Note that the 

channel should use a common reference when measuring, and the ground 

wires of the two probes cannot be connected to two non-isolated places with 

different DC electrical levels, otherwise it may cause a short circuit due to the 

ground wire connection of the oscilloscope probe. 

Warning: 

Note that the channel should use a common reference when measuring, 

otherwise it may cause a short circuit due to the ground wire connection of the 

oscilloscope probe. 

 

Schematic diagram of the internal ground wire connection of the oscilloscope: 

Ground Clip

Signal Input

Electrical Outlet

Probe

AC Adapter

Oscilloscope

 

Schematic diagram of internal ground connection when oscilloscope is 

connected with computer through the port: 

Ground Clip

Signal Input

Oscilloscope

PC

Electrical Outlet

Probe

USB Cable

 

 

When the oscilloscope is AC powered by adapter or connected with AC 

powered computer through the port, it is not allowed to measure the primary 

power supply of power grid. 

Содержание MP720780

Страница 1: ...Handheld Oscilloscope Quick Guide MP720780 MP720781 MP720782 and MP720783...

Страница 2: ...tion to the User Interface of the Oscilloscope 9 Functional Check 10 Probe Compensation 11 Probe Attenuation Coefficient Setting 12 Safe Use of Probe 13 5 HOW TO USE THE MULTIMETER 14 About This Chapt...

Страница 3: ...ement control and laboratory use EN61326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements EN61000 3 2 2000 A2 2005 Limits for harmonic current emissions equipmen...

Страница 4: ...y appear on this product Danger Indicates an immediate hazard or injury possibility Warning Indicates a possible hazard or injury Caution Indicates potential damage to the instrument or other property...

Страница 5: ...ction of the oscilloscope probe Warning Note that the channel should use a common reference when measuring otherwise it may cause a short circuit due to the ground wire connection of the oscilloscope...

Страница 6: ...ope When testing in a CAT II environment do not connect a voltage higher than 400 V to any input port When testing in a CAT II environment do not connect a voltage with a voltage difference of more th...

Страница 7: ...d make a check on the instrument according to the following steps 1 Check whether there is any damage caused by transportation If it is found that the packaging carton or the foamed plastic protection...

Страница 8: ...Use the Oscilloscope The Structure of the Oscilloscope Front Panel and Keys The front panel and keys of the oscilloscope are shown in Figure 4 4 11 6 7 9 10 16 15 14 13 12 5 17 3 8 1 2 Figure 4 Front...

Страница 9: ...illoscope or range key multimeter 8 Zoom or move key Function of direction keys used for the up and down movements of waveform the time base changing the voltage cursor movements and the trigger of el...

Страница 10: ...8 Side Panel 1 2 3 Description 1 Probe compensation 3 3V 1kHz square wave signal output 2 Charging or USB communication interface 3 Bracket...

Страница 11: ...ained and the oscilloscope is ready Scan Scan mode Continuously collect and display waveform data Stop Stop collecting waveform data 2 Run stop 3 Time base display 4 The pointer indicates the trigger...

Страница 12: ...he channel is not open 15 The pointer indicates the grounding reference point zero position of the waveform displayed in CH1 channel If there is no pointer indicating the channel it means that the cha...

Страница 13: ...When connecting the probe to any input channel for the first time make this adjustment to match the probe with the input channel The probe without compensation or deviation compensation will lead to m...

Страница 14: ...e 0 3 Probe Adjustment Probe Attenuation Coefficient Setting The probe has a variety of attenuation coefficients which will affect the vertical position factor of the oscilloscope To change check the...

Страница 15: ...e setting value of the probe switch is 1X and 10X See Figure 04 Figure 0 4 Probe Attenuation Switch Note When the attenuation switch is set to 1X the probe limits the bandwidth of the oscilloscope to...

Страница 16: ...aking any measurements connect the probe to the instrument and connect the ground terminal to the ground 5 How to Use the Multimeter About This Chapter This chapter introduces the multimeter function...

Страница 17: ...ge 4 Indicating that there is a USB cable inserted 5 Battery power indication 6 Hold can keep the current reading on the display 7 Measurement value and unit 8 Display of switching resistance buzzer d...

Страница 18: ...Connect the BNC cable to the port marked GEN Out in the top of the oscilloscope Generator Output Ports To observe the output of the waveform generator connect the other end of the BNC cable to the si...

Страница 19: ...to the multimeter the measurement type is displayed as E It may be that the measurement type was not selected At this time press F4 the measurement type should display the corresponding measurement ty...

Страница 20: ...e If so center the trigger electrical level or set the trigger mode to automatic In addition you can press Auto to automatically complete the above settings 7 In the oscilloscope state the display spe...

Страница 21: ...irect sunlight for a long time Caution Do not let spray liquid or solvent touch the instrument or probe to prevent damage to the instrument or probe Cleaning Check the instrument and probe frequently...

Страница 22: ...power for about 6 hours The power supply and battery indicator symbols in the upper right corner of the screen are explained as follows symbol indicates the power on charging status symbol indicates...

Страница 23: ...and only lithium batteries of the same specification can be used INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL ELECTRONIC EQUIPMENT When this product has reached the end of its life it mus...

Отзывы: