multicomp pro MP720780 Скачать руководство пользователя страница 22

 

 

20 

Do not use any abrasive chemical cleaning agent to avoid damaging the 

instrument or probe. 

Warning

: Please make sure the instrument is dry before re-energizing 

to avoid electrical short circuit or personal injury caused by moisture. 

Charging and Replacement of Battery 

If you want to store the oscilloscope for a long time, it is recommended to fully 

charge the lithium battery before storing. 

Battery Charging 

The  lithium  battery  may  not  be  fully  charged  when  delivered.  To  make  the 

battery fully charged, it takes up to 4.5 hours (when the device is turned off) or 

it is  subject to the charging indicator.  After charging, the battery can supply 

power for about 6 hours. 

The power supply and battery indicator symbols in the upper right corner of 

the screen are explained as follows: 

  symbol indicates the power-on charging status; 

  symbol indicates battery power supply; 

  symbol indicates that there is  only  about five minutes  of use time left. 

Please  charge  as  soon  as  possible  according  to  the  relevant  tips  to  avoid 

damage to the battery. 

Charging Method 

Charging the battery through the power adapter: Connect the oscilloscope to 

the power socket through the USB data cable  and power  adapter delivered 

with the machine for charging. 

Charge the oscilloscope through the USB interface: Connect the oscilloscope 

to a computer or other equipment through a USB data cable for charging (pay 

attention  to  the  load  capacity  of  the  power  supply  equipment  to  avoid 

abnormal operation of the equipment). 

Содержание MP720780

Страница 1: ...Handheld Oscilloscope Quick Guide MP720780 MP720781 MP720782 and MP720783...

Страница 2: ...tion to the User Interface of the Oscilloscope 9 Functional Check 10 Probe Compensation 11 Probe Attenuation Coefficient Setting 12 Safe Use of Probe 13 5 HOW TO USE THE MULTIMETER 14 About This Chapt...

Страница 3: ...ement control and laboratory use EN61326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements EN61000 3 2 2000 A2 2005 Limits for harmonic current emissions equipmen...

Страница 4: ...y appear on this product Danger Indicates an immediate hazard or injury possibility Warning Indicates a possible hazard or injury Caution Indicates potential damage to the instrument or other property...

Страница 5: ...ction of the oscilloscope probe Warning Note that the channel should use a common reference when measuring otherwise it may cause a short circuit due to the ground wire connection of the oscilloscope...

Страница 6: ...ope When testing in a CAT II environment do not connect a voltage higher than 400 V to any input port When testing in a CAT II environment do not connect a voltage with a voltage difference of more th...

Страница 7: ...d make a check on the instrument according to the following steps 1 Check whether there is any damage caused by transportation If it is found that the packaging carton or the foamed plastic protection...

Страница 8: ...Use the Oscilloscope The Structure of the Oscilloscope Front Panel and Keys The front panel and keys of the oscilloscope are shown in Figure 4 4 11 6 7 9 10 16 15 14 13 12 5 17 3 8 1 2 Figure 4 Front...

Страница 9: ...illoscope or range key multimeter 8 Zoom or move key Function of direction keys used for the up and down movements of waveform the time base changing the voltage cursor movements and the trigger of el...

Страница 10: ...8 Side Panel 1 2 3 Description 1 Probe compensation 3 3V 1kHz square wave signal output 2 Charging or USB communication interface 3 Bracket...

Страница 11: ...ained and the oscilloscope is ready Scan Scan mode Continuously collect and display waveform data Stop Stop collecting waveform data 2 Run stop 3 Time base display 4 The pointer indicates the trigger...

Страница 12: ...he channel is not open 15 The pointer indicates the grounding reference point zero position of the waveform displayed in CH1 channel If there is no pointer indicating the channel it means that the cha...

Страница 13: ...When connecting the probe to any input channel for the first time make this adjustment to match the probe with the input channel The probe without compensation or deviation compensation will lead to m...

Страница 14: ...e 0 3 Probe Adjustment Probe Attenuation Coefficient Setting The probe has a variety of attenuation coefficients which will affect the vertical position factor of the oscilloscope To change check the...

Страница 15: ...e setting value of the probe switch is 1X and 10X See Figure 04 Figure 0 4 Probe Attenuation Switch Note When the attenuation switch is set to 1X the probe limits the bandwidth of the oscilloscope to...

Страница 16: ...aking any measurements connect the probe to the instrument and connect the ground terminal to the ground 5 How to Use the Multimeter About This Chapter This chapter introduces the multimeter function...

Страница 17: ...ge 4 Indicating that there is a USB cable inserted 5 Battery power indication 6 Hold can keep the current reading on the display 7 Measurement value and unit 8 Display of switching resistance buzzer d...

Страница 18: ...Connect the BNC cable to the port marked GEN Out in the top of the oscilloscope Generator Output Ports To observe the output of the waveform generator connect the other end of the BNC cable to the si...

Страница 19: ...to the multimeter the measurement type is displayed as E It may be that the measurement type was not selected At this time press F4 the measurement type should display the corresponding measurement ty...

Страница 20: ...e If so center the trigger electrical level or set the trigger mode to automatic In addition you can press Auto to automatically complete the above settings 7 In the oscilloscope state the display spe...

Страница 21: ...irect sunlight for a long time Caution Do not let spray liquid or solvent touch the instrument or probe to prevent damage to the instrument or probe Cleaning Check the instrument and probe frequently...

Страница 22: ...power for about 6 hours The power supply and battery indicator symbols in the upper right corner of the screen are explained as follows symbol indicates the power on charging status symbol indicates...

Страница 23: ...and only lithium batteries of the same specification can be used INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL ELECTRONIC EQUIPMENT When this product has reached the end of its life it mus...

Отзывы: