7. Turn on the output terminal again and check if display shows (CV).
8.  If display shows (CC), either your preset current limiting value is too low or your load requires more voltage and current. 

You need to re-access the voltage and current requirement of your load and increase the voltage or current accordingly 

until (CV) appears.

Connecting the 3 outputs 

(using NTP -6531, 1-36V, 0.25-3A as an example)

All the three outputs are fully isolated from ground and with each other so that it is possible to make cross connections to power 

a circuit board or device that requires for example: +3 or +5V, +12 V or -12V and 1-36V as shown in Fig.1.
The variable main output is set for 12V and it is assigned as the +12V source (available maximum current 3A)
Note the variable main output can be set for other voltage (1-36V) such as 16V.
The fixed 12V is made as the - 12V source (available maximum current 0.5A)
The fixed 5V is made as the +5V source. (available maximum current 0.5A)

Connecting outputs in series

 (using NTP-6531 as an example)

You can have a 17V fixed output by connecting the 5V in series with the 12V outputs.
The 2 outputs (Aux.1) can be connected in series to make a variable 5V to 41V with maximum current 2A (Fig. 2)
The 3 outputs can be connected in series to make a variable 17V to 53V with maximum current 1A, (Fig. 3)
There are other combination of cross connections for different positive and negative output voltages.

Содержание MP710079

Страница 1: ...com multicomp pro sg element14 com b multicomp pro User Manual Switching Mode Power Supply with USB Remote Control Part Number MP710079 MP710080 MP710081 MP710079 US MP710080 US MP710081 US MP710079...

Страница 2: ...an provide 3 outputs at the same time All three outputs are fully isolated so different cross connections of 2 or 3 outputs can provide various fixed or variable output voltages Any output can be conn...

Страница 3: ...current is less than the preset current limit ing value When the load current is equal to or greater than the preset current limiting value the power supply will automati cally cross over to the cons...

Страница 4: ...ice that requires for example 3 or 5V 12 V or 12V and 1 36V as shown in Fig 1 The variable main output is set for 12V and it is assigned as the 12V source available maximum current 3A Note the variabl...

Страница 5: ...decrease to zero to prevent damage to power supply When the temperature inside the power supply returns to normal then the power supply will automatically return to operation again PC Connection The N...

Страница 6: ...dication CC CV Amp Volt Output ON OFF Aux output current Protection Short Circuit Overload Over Temperature Tracking OVP CE Approvals LVD EN 61010 EMC EN 55011 Cooling System Natural Convection Dimens...

Страница 7: ...CR OK CR Get Setting Volt Curr voltage 0 3640 current 0 5100 Input Command GETS CR Return Value 500 1000 CR OK CR Meaning The Memory setting voltage value is 5 00V and Current is 1 000A Input Command...

Страница 8: ...ability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to limit or restrict the Group s liability for death...

Отзывы: