INSTALLATION
4
What you need
For installation you need to have the following tools available:
– Electric drill
– Hole saw (55 mm) or Compass saw
– Saw
– Measuring tool
– Asphalt sealant/adhesive
Also check that the floor area where the toilet is to be positioned is large enough. The floor area required is:
Model 15,25 and 55 width 55 cm x length
11
0 cm (for the toilet and removal of the tray).
Model 65 width 65 cm x length
1
35 cm (for the toilet and removal of the tray).
Pipe installation
All pipes going through the ceiling into cold spaces (e.g. the attic) must be insulated.
This is to
prevent draughts and condensation in the ventilation pipe. Insulation is essential, regardless of how much
or how little the toilet is used. Do not use pipe bends over 45°.
Do not use a rain cap on top of the
ventilation pipe
- the air must be allowed to flow freely. Only the insect netting should be on top of
the pipe.
Temperature
The room in which the toilet is installed must be insulated.
When the toilet is in use the room
temperature must be at least
1
8°C to ensure it functions properly.
The easiest thing to do is to
install a thermostatically controlled radiator.
If the toilet is not in use then the temperature
need not be
controlled,
low temperatures will not damage the unit.
Air supply
In order to ensure adequate air supply, a vent should be installed in the exterior wall.
The exhaust
air is evacuated through the toilet. Avoid having a bathroom fan in the toilet room as it creates a back draught,
which can lead to odours in the room.