Mod. 6609-12d: Automatic Forms Cutter
31.05.2006
-23-
MEASUREMENT-POINTS (Fibre-Optic) at PC-Board
1 ) Analogue-output Amplifier for encoding-disks with running motors:
Testpin 1 and 2 Cross-Cutter:
Scope square (trapezoid) signal 1V - 11V
(start servive routine 011/012, disconnect
function of the cutting blade (follow the
instructions at chapter 3, Pos. 17) -
harmonious speed.)
Testpin 3 and 4 Traktor:
Scope-square (traapezoid) signal 1V - 11V
(start service routine 013/014 - harmonious
speed.)
In the case, that the meassurements on testpin 1+2 and 3+4 are not showing the same results,
the encoder disc must be checked or the board must be changed.
2 ) Analogue-outputs Amplifier for OMR and Papersensor:
Testpin 5 (spare for optional sensor)
Testpin 6 OMR spare channel
Testpin 7 OMR standard:
Scope trapezoid signal 1V - 11V (
white paper under the head, start
service routine 017, or reading
routine 1, EZ = 010. START, most
upper position of the signal must be
3 sec. flat.
Testpin 8 paper sensor:
Square signal 1V - 11V ( with paper
over the
sensor).
3 ) Further signals (digital signals):
Encoder-signals after Schmitt-Trigger:
Testpin 19 (OPTO 1), Testpin 20 (OPTO 2),
Testpin 17 (OPTO 3), Testpin 18 (OPTO 4):
Square signal 0V - 5V, 50%
Papersensor:
Testpin 21 (OPTO 5), Testpin 22 (OPTO 8): DC-voltage 0V with paper, 5V without
paper
Содержание 6609d
Страница 1: ...Service Instructions Automatic Forms Cutter Modell 6609d 6612d Stand 31 05 2006 ...
Страница 4: ...Mod 6609 12d Automatic Forms Cutter 31 05 2006 4 ...
Страница 19: ...Mod 6609 12d Automatic Forms Cutter 31 05 2006 19 ...
Страница 22: ...Mod 6609 12d Automatic Forms Cutter 31 05 2006 22 Measurement Points PC Board ...