"File" menu 
 

This program menu allows you to load and store multi transducer configurations. The configuration files are denoted 
by  the  file  type  *.mkg.  The  configurations  of  the  different  Multi-MU  types  are  compatible  with  each  other.  With 
each configuration file is a text file stored, in which information  on such as project descriptions, location,  etc. are 
stored. The entries for the text file can be entered in the "System / Project" input field in the menu "Options". You 

can also print the configuration and cancel the “Multi

-E11/E4/E-

MU Tool” application.

 

 

 
"Measured values" menu 

 

This menu entry opens a window in which the Multi-E11/E4/E-MU measured values can be displayed and stored. If 
the  transfer  of  measured  values  has  already  started,  then  the  Multi-E11/E4/E-MU  configuration  units  and 
notifications  are  automatically  adjusted.  Incorrect  selection  of  the  measurement  transducer  displays  an  error 
message. Please then restart the program! 
The  time  intervals,  at  which  the  measured  values  are  read  out,  can  be  set  by  the  updating  rate.  The  adjustment 

range is between 1 and 600 seconds. To store the measured values, click on “Measured values store” 

before 

starting 

the measurements. Enter the file name under which the measured values are to be stored, as well as the file format 
in the window. You can choose between text file *.txt and excel file *.csv. With the text file, the tab button is used to 
separate the measured values and, with the excel file, a semicolon sign 

“ ; " is used. The measured values are stored 

at the time interval set by the refresh rate. The measured values are stored with their time and date. Click on “End 
measurement” or “Close” to cancel the measurement and/or data collecti

on. A 

click on “Reset 

kwh / 

kvarh“ 

reset 

the kWh- and kvarh-counter. The operating hours counter 

can’t be

 reset. 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 
 

                 

„Measured values“ menu

 

 
 
 

"Send configuration" menu 
 

Configuration data can be transmitted using this button without you being able to recheck the data in the overview. 
It  is  used  to  transfer  the  data  to  the  Multi-E11/E4/E-MU  more  quickly  and  more  easily.  Incorrect  selection  of  the 
measurement transducer displays an error message. Please then restart the program! 
 

 
 
 

Содержание Multi-E-MU

Страница 1: ...Guide Multi E11 E4 E MU Tool M LLER ZIEGLER GmbH Industriestr 23 D 91710 Gunzenhausen Tel 49 0 98 31 50 04 0 Fax 49 0 98 31 50 04 20 www mueller ziegler de info mueller ziegler de...

Страница 2: ...u 11 Current L1 L2 L3 menu 12 Frequency menu 13 Power cos phi menu 14 Men Outputs 1 4 only Multi E4 MU 15 File menu 16 Measured values menu 16 Send configuration menu 16 Read configuration menu 17 Lan...

Страница 3: ...stored in a text or excel file In this way series of measurements can be logged over very long periods of time and graphically evaluated Data transmission takes place via an Ethernet LAN interface wi...

Страница 4: ...is password protected You may change the username and the password in the settings The default user name is admin and the default password is 123multi Website Network CAUTION Incorrect settings may ca...

Страница 5: ...ng button The selected time interval Save Intervall determines the interval between saving of the measured values The measured values are saved in file value csv Always only one measured value file ca...

Страница 6: ...var kvar Mvar measured value reactive power L3 6 unit reactive power L3 4 var kvar Mvar measured value reactive power sum 6 unit reactive power sum 4 var kvar Mvar measured value apparent power L1 6 u...

Страница 7: ...L2 D Current L3 E Voltage L1 N L1 L2 F Voltage L2 N L2 L3 G Voltage L3 N L3 L1 H Frequency I Active power import J Active power export K Reactive power inductive L Reactive power capacitive M Apparent...

Страница 8: ...tion Place the program CD Multi E11 E4 E MU Tool in the CD DVD drive of your computer If the installation routine does not start automatically open the file setup exe on the program CD Follow the inst...

Страница 9: ...ect the program s language Options menu This program menu allows you to read or send the configuration from the Multi E11 E4 E MU Type in the text box IP address or host name the corresponding data of...

Страница 10: ...ed If minimum is selected the G1 limit value is activated once the value falls below the set limit value Important The limit output hysteresis amounts to approx 4 of the set limit value Limit value an...

Страница 11: ...configuration button Once this button has been activated the configuration data is read from the Multi E11 E4 E MU and displayed in the program Incorrect selection of the measurement transducer displ...

Страница 12: ...primary voltage in the box Transformers primary voltage in volts Transformer voltages of up to 60000 V can be entered Voltage measurement between For alternating current or 4 wire networks select a vo...

Страница 13: ...s with a secondary current of 1 A or 5 A When measuring current on current transformers enter the current transformers primary current in the box Transformer primary current in amps Transformer curren...

Страница 14: ...he power rating power factor and the respective outputs The power rating can be configured for energy supply or energy transfer or for both energy directions Inputs of 0 50000 can be made in three mea...

Страница 15: ...nu Multi E4 E MU Outputs 1 4 menu only Multi E4 MU This program menu allows you to configure the 4 analogue outputs Any measured variable can be assigned to each output but every measured variable can...

Страница 16: ...asured values are read out can be set by the updating rate The adjustment range is between 1 and 600 seconds To store the measured values click on Measured values store before starting the measurement...

Страница 17: ...e g 192 168 2 2 or e g Multi E11 MU and the port numbered 9760 Send a TCP IP packet with the following hex values 0xBD 0x57 The smallest interval for reading out the values should not be less than 50...

Страница 18: ...kvar Mvar measured value apparent power L1 6 unit apparent power L1 3 VA kVA MVA measured value apparent power L2 6 unit apparent power L2 3 VA kVA MVA measured value apparent power L3 6 unit apparen...

Страница 19: ...ing of the Multi E11 E4 E MU is via its IP address or web address e g http multi e11 mu dyndns org httpvalue xml and the request for file httpvalue xml The measuring transformer s reply is a string co...

Страница 20: ...power sum 6 unit reactive power sum 4 var kvar Mvar measured value apparent power L1 6 unit apparent power L1 3 VA kVA MVA measured value apparent power L2 6 unit apparent power L2 3 VA kVA MVA measur...

Страница 21: ...Multi E11 E4 E MU can be read out using the MODBUS TCP protocol Connect the transmitter with a LAN cable to your PC or a router with the MODBUS master The addressing of the Multi E11 E4 E MU is via it...

Страница 22: ...measured value active power L3 INT W 1 0x000B measured value active power sum INT W 1 0x000C measured value reactive power L1 INT var 1 0x000D measured value reactive power L2 INT var 1 0x000E measur...

Страница 23: ...ergy reference impulses output at output G1 or Reactive energy inductive impulses output at output G2 1 Current L1 2 Current L2 3 Current L3 4 Voltage L1 N L1 L2 5 Voltage L2 N L2 L3 6 Voltage L3 N L3...

Отзывы: