6.4.4
Boom section switch
The function of the boom section switch is to switch the individual boom sections. If a switch is off, then the corresponding
boom section is also switched off and cannot be switched on by means of the boom section main switch
.
6.4.5
Configuring the section switches
If you connect a Spraydos with nine section switches to a sprayer with five sections, you can set that only every second
switch is used. In doing so, please note that the LEDs above unused switches are also illuminated as soon as they are
switched up.
Diagram 6-2 Section switches
On the left: Every second switch controls one valve (Configuration 1:0); on the right, the first five switches control
the valves (Configuration 1:1)
>
Reboot the computer.
>
Press the
and
keys (in this sequence) simultaneously.
>
The current configuration appears on the display:
>
Set the value using the
and
keys.
>
Press the
key to adopt the new value.
>
Reboot the computer.
6.5
Hydraulic functions switch
6.5.1
Short SPRAYDOS version
The short SPRAYDOS version supports a maximum of 4 hydraulic functions. For this purpose up to 4 switches can be
mounted on the top right-hand area of the computer. The function of each of these switches is illustrated by the pictograms
on the tactile keyboard.
6.5.2
Long SPRAYDOS version
The long SPRAYDOS version has an additional row of switches underneath the section switches. Here, up to 10 hydraulic
functions as well as foam markers and corner nozzles can be accommodated. Pictograms illustrate their function.
6.6
Operating procedure
Once the machine data have been entered (6.2.1- 6.2.6), only the start function (6.3.1) has to be activated before
operation can begin. During operation all values can be called up.