7
Configuring the job computer for work
Configuring the fill level sensor
48
V4.20191001
30322453-02-EN
3.
- Call up the “
CALIBRATION
” screen.
4.
- Start the calibration.
5.
Apply several hundred litres of water.
⇨
While applying, the counted impulses are shown in the “
Counted Impulses
” field.
6.
- Stop the calibration.
7.
Enter the quantity of the applied water in the “
Quantity
” field.
⇨
You have successfully calibrated the flow meter.
8.
As an option, you can configure the “
Correction Factor
” and “
Flow Meter Impulses
”
parameters.
“Correction Factor” parameter
Enter a factor with which the current tank content should be multiplied.
Only use this parameter if the displayed tank content does not correspond to the actual tank content.
The standard set value is “1.000”.
“Flow Meter Impulses” parameter
Enter the number of impulses for the flow meter manually if you have already previously calibrated
the flow meter.
Configuring the fill level sensor
If you are working with fill level sensors, they must be configured before using for the first time.
Use the following function keys to operate the function:
Function icon
Meaning
Saves the minimum fill level of the tank.
Saves the maximum fill level of the tank.
1.
On the work screen, press:
> (
) >
2.
If you know the minimum and maximum fill levels of the tank, you can optionally enter the
“
Minimum Volume
” and “
Maximum Volume
” parameters. Otherwise, proceed with the following
step:
3.
Empty the tank completely.
7.3.1
7.3.2
7.4
Controls
Procedure