Operating job computer on the field
Controlling the application
Setting target rate
Use the following parameter on the “
SETTINGS
” screen to define how much slurry should be applied
on an area.
▪
“
Target Rate
”
Defines how much slurry should be applied per hectare.
▪
“
Unit
”
Defines the unit that should be used for the metering, depending on whether you want to
measure the volume or the mass.
– “
Regul. (Vol.)
”
– “
Regul. (Mass)
”
– “
Reg. Phosphorus
”
– “
Reg. Nitrogen
”
– “
Reg. Ammonia
”
– “
Reg. Pottasium
”
▪
“
Density
”
Defines the density of the slurry.
▪
“
Regul. factor
”
Defines the adjustment of the flow rate for the speed. This should ensure that the applied volume
of slurry corresponds exactly to the defined target rate.
The regulation factor adjusts the reaction speed of the regulation:
– The higher the regulation factor, the faster the flow rate is adjusted.
– The lower the regulation factor, the more slowly the flow rate is adjusted.
When setting the regulation factor, you can pay attention to the following:
– If, during movement at constant speed, the current application rate jumps around the target
rate, you need to reduce the regulation factor.
– If, when the speed changes, the application rate does not adjust to the target rate quickly
enough, you need to increase the regulation factor.
1.
On the work screen, press:
⇨
The “
SETTINGS
” screen appears.
2.
Configure the parameters.
Starting and stopping the application
This is how you reach the screen with this function: