Configuring the job computer
Entering sprayer parameters
7
3030383000-02-EN
V1.20190404
41
“Maximum Pressure” parameter
This setting defines the maximum pressure up to which the spraying pressure is optimal.
If the spraying pressure increase beyond the defined pressure, an alarm is issued.
If no pressure sensor is installed on your sprayer, you must enter “0” as the value.
“Sprayer off Below” parameter
(Minimum working speed)
If the sprayer speed drops below the minimum working speed, the following happens:
▪
Application will be switched off automatically.
▪
The work screen displays the icon
When the value is set to 0, this function is deactivated.
“Regulation off Below” parameter
If the sprayer falls below this speed, the following happens:
▪
The flow will no longer be regulated and the flow remains unchanged.
▪
Manual mode will be activated.
▪
The work screen displays the icon
When the value is set to 0, this function is deactivated.
This parameter must be higher or the same as the “Sprayer off below” parameter.
“Regulation Factor” parameter
In Automatic mode, the spray pressure of the nozzles is adapted to the current speed of the sprayer.
The adjustment should ensure that the volume of spray liquid that is applied is exactly what you
defined in the target rate. The regulation factor plays a decisive role here.
The regulation factor adjusts the reaction speed of the regulation:
▪
The higher the regulation factor, the faster the spray pressure is adjusted.
▪
The lower the regulation factor, the more slowly the spray pressure is adjusted.
When setting the regulation factor, you can pay attention to the following:
▪
If, during movement at constant speed, the current application volume jumps around the target
value, you need to reduce the regulation factor.
▪
If, when speed is changing, the application volume does not adjust to the rate quickly enough,
you need to increase the regulation factor.
“Tank Size” parameter
Size of the tank for the spray liquid.
7.1.6
7.1.7
7.1.8
7.1.9
7.1.10