background image

Mueller refers to one or more of Mueller Water Products, Inc. a Delaware corporation (“MWP”), and its subsidiaries. MWP and each of its subsidiaries are legally separate and independent entities when providing products and services. 

MWP does not provide products or services to third parties. MWP and each of its subsidiaries are liable only for their own acts and omissions and not those of each other. MWP brands include Mueller

®

, Echologics

®

, Hydro Gate

®

Hydro-Guard

®

, HYMAX

®

, Jones

®

, Krausz

®

, Mi.Net

®

, Milliken

®

, Pratt

®

, Pratt Industrial

®

, Singer

®

, and U.S. Pipe Valve & Hydrant. Please see muellerwp.com/brands and krauszusa.com to learn more.

© 2020 Mueller Co., LLC. All Rights Reserved. The trademarks, logos and service marks displayed in this document are the property of Mueller Co., LLC., its affiliates or other third 

parties. Products above marked with a section symbol (§) are subject to patents or patent applications. For details, visit www.mwppat.com. These products are intended for use in 

potable water applications. Please contact your Mueller Sales or Customer Service Representative concerning any other application(s). 

 F 14286 10/20

For more information about Mueller or to view our full line of water products, please visit www.muellerwp.com.
For customer support or to report any product issues, please call 1.800.423.1323 or email [email protected].

WARNING

FOR WEAK SIGNAL STRENGTH CONSIDER MOVING 
SMART HYDRANT TO AN ALTERNATE LOCATION 
WITH BETTER CELLULAR COVERAGE. INSTALLATION 
AT CURRENT LOCATION MAY CONTINUE; HOWEVER, 
POOR TRANSMISSION OF CELLULAR SIGNAL, POSSIBLE 
LOSS OF DATA, POOR BATTERY LIFE, AND POTENTIAL 
CHALLENGES RECEIVING OVER AIR UPDATES MAYBE 
ENCOUNTERED WITH CURRENT LOCATION. 

APPENDIX  A

Figure 1: Signal Strength Feedback: Weak

Figure 2: Signal Strength Feedback: Strong

Figure 3: Success Feedback

Содержание SENTRYX SUPER CENTURION

Страница 1: ... proceed through instructions below Note Caution Changes or modifications not expressly approved by Mueller Systems LLC could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in...

Страница 2: ...pletely 3 Open hydrant main valve completely 4 A continuous flow of water no matter how slight indicates hydrant is not properly isolated from the main water supply This issue must be corrected before any hydrant disassembly can proceed i e the water to the hydrant MUST be stopped EQUIPMENT TOOLSNEEDED PPE Hard hat Safety shoes Safety vest Safety glasses Work gloves Tool A 367 brass sleeve A 311 o...

Страница 3: ... remove brass sleeve 6 Remove o ring from upper barrel Slide slotted end of A 359 over top of stem and engage the pin in upper stem Turn T head tightening wrench against stem 7 Pull up on seat wrench to be sure the main valve is completely closed The main valve must be closed or the upper valve plate will be damaged Lower support arm onto top flange of the upper barrel and tighten thumb screw to h...

Страница 4: ...stainless steel lock washer 15 Clean inspect and replace any damaged parts Super Centurion main valve can be reversed to provide a new seal Replace drain valve facings if damaged 16 Reassemble main valve assembly to new lower stem Reverse steps with newly provided brass lower valve nut and tighten to 90 115 ft lbs 17 Assemble the new lower stem via the stem coupling to the upper stem ...

Страница 5: ...to avoid cross threading 21 Reassemble wrench to upper stem Pull up on seat wrench to ensure main valve is completely closed lower support arm and tighten thumb screw while maintaining main valve in the closed position Turn main valve assembly clockwise to 100 190 ft lbs 22 Remove the seat wrench 23 Attach brass sleeve to upper stem and lubricate outside to protect o ring seals from thread damage ...

Страница 6: ... the hold down nut and bonnet o ring 28 Take red plastic spacer and slide over bottom of hold down nut past the o ring and up against the hold down nut shoulder 29 Reassemble operating nut anti friction washer on top thrust collar of operating nut bonnet o ring hold down washer and hold down nut hand tighten to secure in place 30 Torque bonnet bolts 8 to 40 80 ft lbs 31 Torque hold down nut to 200...

Страница 7: ...en drained below the antenna near the top of the lower stem Necessary for the stem to communicate with the bonnet d System water pressure is 20 psi or greater e Re swipe the commissioning tool If success feedback is not received within 5 minutes contact Customer Service Once a Sentryx software enabled Super Centurion has been successfully installed auto locating of hydrant using GPS will automatic...

Страница 8: ... third parties Products above marked with a section symbol are subject to patents or patent applications For details visit www mwppat com These products are intended for use in potable water applications Please contact your Mueller Sales or Customer Service Representative concerning any other application s F 14286 10 20 FormoreinformationaboutMuellerortoviewourfulllineofwaterproducts pleasevisitww...