Much More Water Bluebox 1800 UF Скачать руководство пользователя страница 15

Side 15 af 16 

[IMPORTANT NOTE] 

Please be aware of the following: 

Make sure that the electricity supply is stable.

The  purification membranes in the Bluebox 1800UF system normally have to be changed
every 2 years depending on the working hours and quality of feed water.

Please do not place the system in directly sunlight. Heat may affect the electronics in the
switch board box.

As the UV-light contains glass, the system must not be affected by hard shock.

The system must be free of dust and dirt.

The system must not be exposed for frost. Temperatures below 0 (cero) degrees Celsius can
ruin the membranes. E.g. during a long-haul flight, the Bluebox should be started with low
pressure for a while in order to defrost the membranes without damaging them. For long
term storage in freezing temperatures, please contact www.pureh2o.net
([email protected]).

As an industrial standard for Reverse Osmosis, membranes output decreases with
temperature of raw water. (3% reduction per 1 degree C measured from 25 degree C)

The industrial standard for Ultrafiltration membranes shows a lesser effect from colder feed
water, but the capacity should be expected to be reduced.

Beware of silt, humus and high levels of iron in the raw water. These compounds will
eventually spoil the membranes, since very small “plates” from these compounds will fill up
the membranes over time. The only way to deal with this is to install an improved pre-
filtration system.

Содержание Bluebox 1800 UF

Страница 1: ...Bluebox 1800 UF Operating Manual...

Страница 2: ...Side 2 af 16 BlueBox 1800 UF Customized with UV disinfection and post chlorination system...

Страница 3: ...s red and blue hoses into the quick couplings see ill follow the colour codes red sign red hose blue sign blue hose e g 3 Fill the black absorption tube with water and press the 1 hose into the quick...

Страница 4: ...230 V power supply see ill 2 Before starting the pump makes sure that the blue handle is in open position see ill The Bluebox must not be started with pressure on the 3 pre filters might blast 3 Switc...

Страница 5: ...grey electricity box to check that the UV indicators display shows green light if the UV disinfection option is installed see ill 8 Unclean water will come out of the red hose while drinking water can...

Страница 6: ...urn the blue pressure regulating handle on the main block counter clockwise until the pressure reads 0 bar see ill 2 Let the Bluebox work 1 minute without pressure 3 Press on the red button see ill 4...

Страница 7: ...Rinse them in clean water with a brush Affix the filter and check that the crude filter is placed on top see ill 2 Cleaning of the three pre filters a Screw off the three white filter housings using...

Страница 8: ...on the electric box have to be changed every month Every month 1 Lubrication of the pump The pump is lubricated with grease at the point where the arrow marked grease see ill Remove the black plugs o...

Страница 9: ...for 10 minutes After that the blue handle are turned to Pressure on and the Bluebox 1800UF must work at this setting for 30 minutes at 2 3 bar s of pressure 4 The system must now rinse with clean wate...

Страница 10: ...pH cleaners RoClean P303 and RoClean P3111 This stepwise approach has been found to give good results in the past with each wash reaching deeper layers of the foulant Caution When cleaning with low p...

Страница 11: ...re the differential pressure reaches 40psi or where the flow reaches 10 m3 hr pressure vessel Note the pH temperature differential pressure flowrate and any discolouration changes to the cleaning solu...

Страница 12: ...ble 5 Flush out Remaining Alkaline Solution Rinse out the cleaning tank and then fill it with un chlorinated potable water Rinse each pressure vessel until the conductivity of the outlet is within 20...

Страница 13: ...r and vents are cleaned or changed see clogged ill The pump is letting Tubes are tightened on absorption side in air on pump Clean water Check reasons in Check solutions in pump section capacity falls...

Страница 14: ...fective bulb Change bulb and check whether light housing is tight avoid looking directly at UV light for more than a couple of seconds Transformer is Change transformer please contact defective Pure H...

Страница 15: ...long haul flight the Bluebox should be started with low pressure for a while in order to defrost the membranes without damaging them For long term storage in freezing temperatures please contact www p...

Страница 16: ...PURE WATER ANYTIME ANYWHERE Much More Water A S Staerkendevej 43 DK 4000 Roskilde phone 45 8020 8020 info MuchMoreWater com www MuchMoreWater com July 2013...

Отзывы: