2.2 Lifting requirements
DANGER
Suspended load.
Danger to life!
• Use suitable equipment and lifting devices.
• Never stand beneath a suspended load and keep a safe distance.
• Wear personal protective equipment (e.g. protective helmet, safety shoes).
Lifting requirements for installed heat exchanger
1 Maximum permissible diag-
onal pull 10° (*)
2 Center of gravity
(*) Max. permissible diagonal pull must be observed:
• Max. permissible diagonal pull in longitudinal direction is 10 degrees; simultaneous diagonal pull in trans-
verse direction is impermissible.
• Max. permissible diagonal pull in transverse direction is 10 degrees; simultaneous diagonal pull in longitu-
dinal direction is impermissible.