1.4510.210 – Knock Sensor Error B9
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.211 – Knock Sensor Error B10
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4520.508 – MIC5 Stat Operational error
Red alarm. Initiated by MIC5.
Cause
Corrective action
An operational error has
occurred.
u
Rectify cause of alarm.
1.4520.509 – MIC5 Stat System error
Red alarm. Initiated by MIC5.
Cause
Corrective action
A system error has occurred.
u
Rectify cause of alarm.
1.4520.520 – MIC5 Stat W: temperat. limit reached
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
The device temperature is too
high.
u
Ensure sufficient ventilation in the genset room.
1.4520.521 – MIC5 Stat W: pow output lim reached
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
The power output is too high.
u
Check settings in data record, ignition coils and spark plugs.
1.4520.522 – MIC5 Stat W: invalid coil data
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
The ignition system settings are
invalid.
u
Check settings. Restart ignition control unit.