112514 – HIHI T-Exhaust B4
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
1. Check emission values.
2. Check ignition timing (→ Page 163).
3. Check valve gear (exhaust valves do not close).
112515 – HIHI T-Exhaust B5
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
1. Check emission values.
2. Check ignition timing (→ Page 163).
3. Check valve gear (exhaust valves do not close).
112516 – HIHI T-Exhaust B6
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
1. Check emission values.
2. Check ignition timing (→ Page 163).
3. Check valve gear (exhaust valves do not close).
112517 – HIHI T-Exhaust B7
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
1. Check emission values.
2. Check ignition timing (→ Page 163).
3. Check valve gear (exhaust valves do not close).
112518 – HIHI T-Exhaust B8
Red alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
1. Check emission values.
2. Check ignition timing (→ Page 163).
3. Check valve gear (exhaust valves do not close).
MS15026/00E 2015-05