112702 – HIHI T-Exhaust A2 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 57).
2. Check ignition timing (→ Page 186).
3. Check valve drive (exhaust valves do not close).
112703 – HIHI T-Exhaust A3 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 57).
2. Check ignition timing(→ Page 186).
3. Check valve drive (exhaust valves do not close).
112704 – HIHI T-Exhaust A4 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 57).
2. Check ignition timing (→ Page 186).
3. Check valve drive (exhaust valves do not close).
112705 – HIHI T-Exhaust A5 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 57).
2. Check ignition timing (→ Page 186).
3. Check valve drive (exhaust valves do not close).
112706 – HIHI T-Exhaust A6 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 57).
2. Check ignition timing (→ Page 186).
3. Check valve drive (exhaust valves do not close).
112707 – HIHI T-Exhaust A7 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 57).
2. Check ignition timing (→ Page 186).
3. Check valve drive (exhaust valves do not close).
MS150116/04E 2018-04
| Troubleshooting | 85
TIM-ID: 0000038611 - 006