5.6 Engine – Start
Preconditions
☑
Generator is not connected to network
☑
Start interlock is not active
DANGER
Rotating and moving engine parts.
Risk of crushing, danger of parts of the body being caught or pulled in!
• Before cranking the engine with starter system, make sure that there are no persons in the engine's
danger zone.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
• Wear ear protectors.
Starting the engine
Note:
A max. of 3 engine starting attempts are permitted at a max. fuel supply opening time of 15 seconds respec-
tively. After a max. of 3 unsuccessful start attempts, the fuel supply must be locked. Before attempting to
start the engine again, allow time for sufficient inertization of the exhaust section.
u
Initiate specified engine starting sequence (→ Page 53).
MS150116/04E 2018-04
| Operation | 55
TIM-ID: 0000042719 - 003