1.4520.577 – MIC5 IPE Primary Open Cylinder 8
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 8 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.578 – MIC5 IPE Primary Open Cylinder 9
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 9 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.579 – MIC5 IPE Primary Open Cylinder 10
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 10 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.580 – MIC5 IPE Primary Open Cylinder 11
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 11 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.581 – MIC5 IPE Primary Open Cylinder 12
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 12 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.582 – MIC5 IPE Primary Open Cylinder 13
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 13 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.583 – MIC5 IPE Primary Open Cylinder 14
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 14 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
MS150116/04E 2018-04
| Troubleshooting | 105
TIM-ID: 0000038611 - 006