![MTU 20V4000G44F Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/mtu/20v4000g44f/20v4000g44f_operating-instructions-manual_1852704075.webp)
339 – AL Wiring Cylinder B9
Cause
Corrective action
Short circuit fault in injector
wiring cylinder B9 or injector
faulty.
1. Check wiring of affected injector (→ Page 196).
2. Replace injector (→ Page 110).
3. Contact Service.
340 – AL Wiring Cylinder B10
Cause
Corrective action
Short circuit fault in the injector
wiring for cylinder B10 or injector
defective.
1. Check wiring of affected injector (→ Page 196).
2. Replace injector (→ Page 110).
3. Contact Service.
341 – AL Open Load Cylinder A1
Cause
Corrective action
Disruption fault in injector wiring
to cylinder A1.
1. Check wiring of affected injector (→ Page 196).
2. Contact Service.
342 – AL Open Load Cylinder A2
Cause
Corrective action
Disruption fault in injector wiring
for cylinder A2.
1. Check wiring of affected injector (→ Page 196).
2. Contact Service.
343 – AL Open Load Cylinder A3
Cause
Corrective action
Disruption fault in injector wiring
for cylinder A3.
1. Check wiring of affected injector (→ Page 196).
2. Contact Service.
344 – AL Open Load Cylinder A4
Cause
Corrective action
Disruption fault in injector wiring
for cylinder A4.
1. Check wiring of affected injector (→ Page 196).
2. Contact Service.
345 – AL Open Load Cylinder A5
Cause
Corrective action
Disruption fault in injector wiring
for cylinder A5.
1. Check wiring of affected injector (→ Page 196).
2. Contact Service.
346 – AL Open Load Cylinder A6
Cause
Corrective action
Disruption fault in injector wiring
for cylinder A6.
1. Check wiring of affected injector (→ Page 196).
2. Contact Service.
MS15058/04E 2018-12
| Troubleshooting | 73
TIM-ID: 0000068683 - 006