122 – HI T-ECU
Cause
Corrective action
The temperature at the sensor
inside the ECU exceeded the limit
value. The temperature inside the
housing is too high.
1. Disconnect power supply.
2. Check power supply (plant).
3. Contact Service.
141 – AL Power too high
Cause
Corrective action
The average power value over the
last 24 hours has violated the set
maximum value. The average
power demand was too high.
u
Contact Service.
180 – AL CAN1 Node Lost
Cause
Corrective action
Connection or communication
with a node on CAN bus 1 has
failed.
1. Check engine wiring (→ Page 268).
2. Disconnect power supply, then reconnect.
3. Contact Service.
181 – AL CAN2 Node Lost
Cause
Corrective action
Connection or communication
with a node on CAN bus 2 has
failed.
1. Check engine wiring (→ Page 268).
2. Disconnect power supply, then reconnect.
3. Contact Service.
182 – AL CAN Wrong Parameters
Cause
Corrective action
Incorrect parameter values
entered in data record.
u
Contact Service.
183 – AL CAN No PU-Data
Cause
Corrective action
The ECU expects project
configuration data (PU data) from
the Backup Data Module server
(BDM), e.g. SAM or LOP, during
initial start-up.
u
Contact Service.
MS150123/01E 2017-05
| Troubleshooting | 97
TIM-ID: 0000077157 - 001