6 Troubleshooting
6.1 Troubleshooting
Engine does not turn when starter is actuated
Cause
Corrective action
Battery/UltraCaps low or faulty
u
Charge or replace (→ manufacturer's documentation).
Cable connections faulty
u
Check cable connections for secure seating (→ manufacturer's
documentation).
Starter: Engine cabling, POM or
starter defective.
u
Check if cable connections are properly secured , contact
Service
Engine cabling defective
u
Check (→ Page 160)
Engine / generator control:
Assemblies or connectors
possibly loose
u
Perform visual inspection (→ manufacturer's documentation)
Engine governor: Plug-in
connections loose
u
Checking plug-in connections (→ Page 165)
Running gear blocked (engine
cannot be barred manually)
u
Contact Service
Engine turns on starting but does not fire
Cause
Corrective action
Engine: Too cold
u
Preheat (40 °C)
Poor rotation by starter:
Battery/UltraCaps low or faulty
u
Charge or replace battery/UltraCaps (→ manufacturer's
documentation).
Engine wiring faulty.
u
Check (→ Page 160)
Air in fuel system
u
Vent fuel system (→ Page 95)
Engine governor defective
u
Contact Service
Engine fires unevenly
Cause
Corrective action
Injector defective
u
Check, replace if necessary (→ Page 90)
Engine cabling defective
u
Check (→ Page 160)
Air in fuel system
u
Vent fuel system (→ Page 95)
Engine governor defective
u
Contact Service
42 | Troubleshooting | MS150096/03E 2015-04