Note:
The procedure is only described for the exhaust turbocharger (HP). Checking of the exhaust turbocharg-
er turbine housing (LP) requires separate activities (→ Page 101).
Removing heat shield
1.
Remove screws (1) and take off with hold-
er (2) and washers.
2.
Remove screws (2) and take off with heat
shield (1) and washers.
Removing exhaust pipe insula-
tion
u
Release clamps (1) and remove insula-
tion (2).
110 | Task Description | MS150096/03E 2015-04
TIM-ID: 0000026621 - 005