1.4540.033 – Battery Volt High Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Supply voltage has reached
maximum limit value.
1. Check supply voltage.
2. Check cabling.
1.4540.034 – FGT High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.035 – Delta P High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.036 – FGP High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.037 – Watchdog Reset
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.038 – CAN Flow Demand Failed
Red alarm. Initiated by TecJet.
Cause
Corrective action
TecJet setting is not correct.
u
Check setting.
1.4540.040 – TecJet Shutdown
Red alarm. Initiated by TecJet.
Cause
Corrective action
TecJet combined alarm. At least
one other TecJet alarm is
pending.
u
Rectify cause of alarm.
MS150114/01E 2015-03
| Troubleshooting | 87
TIM-ID: 0000038611 - 002