1.4510.188 – Internal Error
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart knock module.
1.4510.189 – Error Camshaft
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from camshaft sensor
for anti-knock control.
u
Check cabling. Check sensor B 1.3 and replace as necessary.
1.4510.192 – Knock Sensor Error A1
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.193 – Knock Sensor Error A2
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.194 – Knock Sensor Error A3
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.195 – Knock Sensor Error A4
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
72 | Troubleshooting | MS150114/01E 2015-03
TIM-ID: 0000038611 - 002