Fault code No. Full designation
Meaning
Action
Related
parameter
No.
402
AL Open Load Digital In-
put 3
Alarm configuration; Line dis-
ruption on digital input 3; Ca-
bling faulty or no resistance
over switch.
1. Check cabling.
2. Contact Service.;
Check input of tar-
get device.
2.8006.62
7
403
AL Open Load Digital In-
put 4
Alarm configuration; Line dis-
ruption on digital input 4; Ca-
bling faulty or no resistance
over switch.
1. Check cabling.
2. Contact Service.;
Check input of tar-
get device.
2.8006.62
8
404
AL Open Load Digital In-
put 5
Alarm configuration; Line dis-
ruption on digital input 5; Ca-
bling faulty or no resistance
over switch.
1. Check cabling.
2. Contact Service.;
Check input of tar-
get device.
2.8006.62
9
405
AL Open Load Digital In-
put 6
Alarm configuration; Line dis-
ruption on digital input 6; Ca-
bling faulty or no resistance
over switch.
1. Check cabling.
2. Contact Service.;
Check input of tar-
get device.
2.8006.63
0
406
AL Open Load Digital In-
put 7
Alarm configuration; Line dis-
ruption on digital input 7; Ca-
bling faulty or no resistance
over switch.
1. Check cabling.
2. Contact Service.;
Check input of tar-
get device.
2.8006.63
1
407
AL Open Load Digital In-
put 8
Alarm configuration; Line dis-
ruption on digital input 8;
wiring defective or no resist-
ance through the switch.
1. Check cabling.
2. Contact Service.;
Check input of tar-
get device.
2.8006.63
2
408
AL Open Load Em. Stop
Input ESI
Alarm configuration; Line dis-
ruption on the input for
emergency stop; Cabling
faulty or no resistance over
switch.
1. Check cabling.
2. Contact Service.;
Check input of tar-
get device.
2.8006.63
3
410
LO U-PDU
Alarm configuration limit val-
ue 1; Preliminary warning: In-
jector voltage too low.
1. Check cabling.
2. Check power
supply.
3. Contact Service.
2.0141.92
1
411
LOLO U-PDU
Alarm configuration limit val-
ue 2; Main warning: Injector
voltage too low.
1. Check cabling.
2. Check power
supply.
3. Contact Service.
2.0141.92
2
412
HI U-PDU
Alarm configuration limit val-
ue 1; Preliminary warning: In-
jector voltage too high.
1. Check cabling.
2. Check power
supply.
3. Contact Service.
2.0141.93
1
413
HIHI U-PDU
Alarm configuration limit val-
ue; Main warning: Injector
voltage too high.
1. Check cabling.
2. Check power
supply.
3. Contact Service.
2.0141.93
2
414
HI Water Level Fuel Pre-
filter
Alarm configuration limit val-
ue 1; Warning: water level in
fuel prefilter too high.
Drain water.
2.0156.93
1
M015695/03E 2013-03