![MTU 10V2000Mx4 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/mtu/10v2000mx4/10v2000mx4_operating-instructions-manual_1852617026.webp)
HP line between distributor and HP accumulator
1 Jacket pipe
2 O-ring
3 O-ring
4 Thrust ring
5 O-ring
6 Thrust screw
7 Thrust ring
8 O-ring
9 HP line
10 Pressure pipe
Leak-off fuel caused by leakages from the sealing cones or the HP lines is returned to the HP pump, from
where it is routed at atmospheric pressure into a level-monitored leak-fuel tank.
26 | General Information | MS150060/04E 2016-02
TIM-ID: 0000002177 - 005