![MTU 10V2000Mx4 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/mtu/10v2000mx4/10v2000mx4_operating-instructions-manual_1852617135.webp)
8.21.4 Engine Monitoring Unit EMU 7 – Plug connection check
Preconditions
☑
Engine is stopped and starting disabled.
Checking EMU plug connections
1.
Check both connectors on EMU (2) for firm
seating. Ensure that the clips (1) are engag-
ed.
2.
Check screws (3) of cable clamps on EMU (2)
for firm seating. Ensure that cable clamps are
not faulty.
MS150060/04E 2016-02
| Accessories for (Electronic) Engine Governor / Control System | 135
TIM-ID: 0000035355 - 002