8.16 Raw Water Pump with Connections
8.16.1 Raw water pump – Relief bore check
DANGER
Rotating and moving engine parts.
Risk of crushing, danger of parts of the body being caught or pulled in!
• Only run the engine at low power. Keep away from the engine's danger zone.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
• Wear ear protectors.
Raw water pump – Relief bore
check
1.
Check relief bore for oil and coolant dis-
charge.
2.
Stop engine (→ Page 54) and disable engine
start.
3.
Clean the relief bore with a wire if it is dirty.
• Permissible coolant discharge: up to
10 drops per hour.
• Permissible oil discharge: up to 5 drops
per hour.
4.
If discharge exceeds the specified limits, con-
tact Service.
122 | Raw Water Pump with Connections | MS150060/04E 2016-02