background image

 

 

After treatment, it is recommended to apply cold compress to the 

treatment area but not ice. 

It is best not to expose the skin to sunlight for two weeks after 

treatment. 

The skin may become red or erythema after treatment, but these 

symptoms will disappear within six months. 

After treatment, blisters or skin ulcers appear, which can be treated 

with antibiotics or burn ointment. 

Two weeks after treatment, it is recommended to use two to four 

weeks of hydroquinone (2-5%) and hydrocortisone ointment (1%). 

For patients with skin type III or IV, pigmentation may appear within 

two to four weeks after treatment, but it can disappear within three 

months. 

Ⅵ、

Daily maintenance

 

Machine cleaning             

Warning: 

 

1.The circulating cooling water of this equipment must be distilled water, and 

the circulating water must be replaced within one to three months 

2.The machine should be cleaned at least once a week. Turn off the machine and wipe 

the surface of the machine. Take care to avoid liquids flowing into the machine

 

3.Before and after each treatment, disinfect the tools used by the patient 

and the operator, such as hand tools and protective glasses.   

 

Содержание D808 PRO

Страница 1: ...User manual 808nm Diode Laser Hair Removal Machine D808 PRO...

Страница 2: ...CONTENTS 1 Introduction 2 Security 3 System Installation 4 Machine operation 5 Treatment considerations 6 Maintenance 7 Technical description 8 Environmental protection...

Страница 3: ...hs warranty The machine is guaranteed within 36 months from the date of shipment Among them the circuit board touch screen and related accessories are covered by the warranty but consumable items such...

Страница 4: ...on the skin surface The wavelength of the semiconductor laser can penetrate into the hair follicles and does not damage the skin surface like ruby and alexandrine This allows semiconductor lasers to b...

Страница 5: ...Security Motor classification Protection against electric shock Type I Type B Protection level against liquid ordinary equipment Operating mode intermittent and continuous Not suitable for environment...

Страница 6: ...operation Optical security This system is the first type of laser product and has a mark on the laser radiation port of the hand tool When operating the equipment the operator should wear protective g...

Страница 7: ...ll electricity on some parts Therefore please cover all housings Except the manufacturer and its authorized maintenance personnel no one should disassemble the casing otherwise it may cause electric s...

Страница 8: ...orbing substance Do not use the device in an environment with flammable substances Keep the surface of the device clean and use a suitable detergent to clean it before operation If alcohol is used for...

Страница 9: ...A Emergency Switch E Water injection hole B Key Switch F Power Switch C Handle G Power line interface D Handle hanger H Overflow hole I Drain hole...

Страница 10: ...w the overflow nut before adding water pull out the funnel after filling and do not cover the filling nut Keep the air flow of the water tank smooth Plug the power cord into the corresponding power so...

Страница 11: ...se a cart to move the device When moving never tilt the device When moving the device do not push or pull hard you should try to lift the device Machine operation Turn on Turn off Machine switch 1 Bef...

Страница 12: ...Connect the power line Turn on the power switch Turn on the emergency stop switch Use the key to turn on the instrument Operation interface Selection Skin selection interface six kinds of skin select...

Страница 13: ...Extension button hair color selection...

Страница 14: ...working interface Cooling level Cooling regulation 1 4...

Страница 15: ...e width range is 10ms 250ms 3Hz Pulse width range is 10 160ms 4Hz Pulse width range is 10 120ms 5Hz Pulse width range is 10 100ms 6Hz Pulse width range is 10 80ms 7Hz Pulse width range is 10 70ms 8Hz...

Страница 16: ...Y button is pressed When pressing the READY button press the handle switch to start shot Alarm display Display the following content in the prompt box Temperature Turn red and flashing alarm when the...

Страница 17: ...tment 1 Establish customer information files 2 Exclude patients with the above contraindications 3 Determine why the patient seeks treatment and its expectations and tell the patient the course of tre...

Страница 18: ...d from a lower setting parameter and energy is gradually increased to avoid side effects When treating light photoaging skin the parameter selection and scar treatment are similar you can refer to the...

Страница 19: ...5 and hydrocortisone ointment 1 For patients with skin type III or IV pigmentation may appear within two to four weeks after treatment but it can disappear within three months Daily maintenance Machi...

Страница 20: ...umidity ordinary equipment Avoid contact with combustible substances Operation mode continuous First class laser products Environmental protection We have taken environmental requirements into conside...

Страница 21: ...ereby removing the hair for a long time Machine advantages 1 Safe without sinking laser pulse light directly hits the hair follicle melanin the epidermis absorbs less energy so there is no loss of sur...

Страница 22: ...from various parts of the human body such as armpit hair beard lip hair hair bun bikini line and limb hair Skin rejuvenation shrink pores and whiten skin Operating procedures 1 Shaving 1 Before the op...

Страница 23: ...utes and lip hair is about 3 minutes for reference only specific time should be based on hair changes and size of hair removal site Confirmed The clinical end point was observed when the hair follicle...

Страница 24: ...pidermis 7 It is normal to feel hot pain in the pigmented area of the epidermis during treatment 8 Protect hair in non treated areas 9 The continuous working time of the instrument is too long it shou...

Страница 25: ...Patients with hypertension and diabetes 4 Customers with light allergies 5 People who have been working under strong light for a long time and have recently sunburned skin 6 Customers with short term...

Страница 26: ...ghtly warm a few parts will have redness and edema Late reaction the hair protrudes from the hair follicle the longer the hair color the lighter the longer the speed the slower the longer the thinner...

Отзывы:

Похожие инструкции для D808 PRO