I

 7 

I

NOTICE

If you are using a mobile device, ensure cellular data is off.

Depending on your operation system, message can appear, 

that there is no internet access. TempoLink smart assistant 

does not need internet access.

Connecting to the user interface may take longer if Wi-Fi 

and LAN connections are active.

7.  Connection of TempoLink smart assistant to 

smartphone, tablet or computer

Connect to a smartphone, tablet or computer to display the 

graphical user interface of the TempoLink smart assistant.

7.1 Connecting a Wi-Fi enabled device to the 

integrated Wi-Fi access point 

3

Activate Wi-Fi on the device and choose the network 

“TempoLink_xxxx” (xxxx indicates the last four digits of the 

serial number). The default password is the serial number 

printed on the label on the bottom of the TempoLink smart 

assistant. 

Fig. 6: Choose the network “TempoLink_xxxx” in the Wi-Fi 

settings of the Wi-Fi-enabled device

7.2 Connecting a computer via USB connection

The TempoLink smart assistant can also be connected via 

USB. If the computer is Wi-Fi enabled deactivate Wi-Fi on the 

computer before setting up the USB connection.

Connect the USB cable   with the micro USB connector to 

the port labeled “USB” on the TempoLink smart assistant. 

Next, connect the USB type-A connector to a free USB port of 

the computer. The USB connection simulates a network card. 

In the folder “network connections” on the computer the 

connection is shown as “IP-over-USB” or “Remote NDIS”.

3/ 

The integrated Wi-Fi access point does not provide 

internet access

After the connection via Wi-Fi or USB is established, open the 

browser and go to the website-URL: 

tempolink.local

The connection icon in the top right shows the status of the 

connection between the TempoLink smart assistant and the 

sensor.

Fig. 8: Start page of the graphical user interface

Fig. 9: Connection status

Connection status

Green

Information

ON

Connection to sensor is established

Red

Information

ON

Connection to sensor is not established

Blue

Information

ON

Sensor in command mode

NOTICE

Only one device can be connected to the TempoLink smart 

assistant at a time in order to display the graphical user 

interface.

NOTICE

Disable all Wi-Fi and LAN connections before connecting 

TempoLink smart assistant via USB. Connecting to the user 

interface may take longer if Wi-Fi and LAN connections 

are active. It may be useful to press CTRL + F5 to delete 

cached text and images from prior to launching the 

tempolink.local

 website.

USB connector

Fig. 7: USB port on the TempoLink smart assistant

8.  Establishing a connection via browser

Содержание Temposonics TempoLink Smart Assistant

Страница 1: ...GENERATION I AM V THE NEW Temposonics Magnetostrictive Linear Position Sensors TempoLink Smart Assistant Operation Manual...

Страница 2: ...oLink smart assistant to power supply 6 6 1 Using the plug in power supply with plug adapters 6 6 2 Using the cable for insertion in an existing sensor power supply with sensor mating connector and ba...

Страница 3: ...mation required for correct operation provided in the product documentation NOTICE 2 1 Intended use This product may be used only for the applications defined under item 1 and item 2 and only in conju...

Страница 4: ...egularly and provide documentation of the checks 7 Before applying power ensure that nobody s safety is jeopardized by starting machines 2 4 Safety instructions for use in explosion hazardous areas Th...

Страница 5: ...1 A D 6 0 Cable with M16 female connector 6 pin for connection type D60 Analog part no 254 989 1 DELIVERY TempoLink smart assistant kit TempoLink smart assistant Power supply or cable for insertion i...

Страница 6: ...ries V sensor of 30 m OUTP UT INPU T SENS OR 24V DC 5 Connection of TempoLink smart assistant to R Series V sensor OUTP UT INPU T SENS OR 24V DC OUTP UT INPU T SENS OR 24V DC 6 Connection of TempoLink...

Страница 7: ...USB connector to the port labeled USB on the TempoLink smart assistant Next connect the USB type A connector to a free USB port of the computer The USB connection simulates a network card In the folde...

Страница 8: ...Use the dialog to navigate to the location where you saved the firmware update file and select the update tar file The selected file is displayed To execute the update click the SUBMIT button Fig 12 N...

Страница 9: ...By clicking the red arrow in the left information about the sensor statistics are displayed depending on the connected sensor Odometer Total distance travelled by the position magnet Magnet cycles To...

Страница 10: ...ial number and order code 9 4 Menu Item Parameters The Parameter menu includes information about the operational settings and the statistics settings of the connected sensor The displayed parameters d...

Страница 11: ...mart assistant and website LED color Information Red ON Website not accessed Green Flashing Data transfer between TempoLink smart assistant and website LED C USB Wi Fi connection LED color up Informat...

Страница 12: ...com JAPAN Branch Of ce Phone 81 3 6416 1063 E mail info jp mtssensors com www mtssensors com MTS Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States M...

Отзывы: