background image

19

Premier Climax Logger Steam Engine

LYS

Remedy

Once in LYS, the engine doesn’t go 
into reverse.

When the LYS enters its last 
sequence the bell automatically 
comes on.

When LYS is enabled, pressing the 
whistle and bell buttons has no effect.

I push the direction button but the next 
sound clip in the sequence does not 
play or the engine does not come out 
of LYS after fourth press of the 
direction button.

So that LYS effects can be as realistic 
as possible, 

Proto-Sound 2.0 

disables the reversing unit 
whenever LYS is enabled.  This 
way the engine remains still at its 
stop as the operator cycles 
through the LYS sequences.

LYS is programmed to start ringing 
the bell at that point.  After 
approximately 12 rings of the bell, 
it will automatically turn off.

Because LYS must control various 
effects in each sequence, Proto-
Sound 2.0 takes control of these 
sound effects until you exit LYS.

Each LYS clip must play for approx. 
30 seconds before LYS will advance 
to the next step in the LYS cycle.  Wait 
at least 30 seconds in each LYS 
sound clip before pressing the 
direction button.

Compatibility

This engine will operate on any traditional O-31 or larger O Gauge track
system, including M.T.H.’s RealTrax

®

 or ScaleTrax

 or traditional tubular

track. It is also compatible with most standard AC transformers.  (See page 19 
for a complete list of compatible transformers and wiring instructions.)

Содержание PREMIER CLIMAX LOGGING STEAM ENGINE

Страница 1: ...her 3 rail locomotives rolling stock and accessories This locomotive is equipped with Proto Sound 2 0 with Digital Command System DCS This new system will allow you to operate your locomotive in Comma...

Страница 2: ...ntrol 8 Lock into a Direction 9 Reset to Factory Defaults 9 Automatic Sounds 9 Maintenance 10 Lubrication and Greasing Instructions 10 Cleaning the Wheels Tires and Track 12 Locomotive Traction Tire R...

Страница 3: ...use damage See the ProtoSmoke Unit Operation section of this book for more information on smoke unit maintenance 3 You should lubricate all side rods and linkage components and pickup rollers to preve...

Страница 4: ...to ring from the time you turn it on until you press and release the button again to turn it off Direction Your train is programmed to start in neutral The first direction after neutral upon start up...

Страница 5: ...sing Proto Sound 2 0 features in order to prevent harm to yourself or your equipment Activating Proto Sound 2 0 Conventional Mode Features Proto Sound 2 0 features are activated by sequences of Bell a...

Страница 6: ...ily disabled so that the train will not move as you use the Direction button to trigger the sounds and Proto Sound 2 0 has disabled operator control over the Whistle and Bell buttons until the full LY...

Страница 7: ...the engine to run the LYS Otherwise the engine without LYS will begin vibrating on the track as its motors strain to move the train since they cannot be automatically disabled during the LYS cycle If...

Страница 8: ...n and the engine will maintain the speed you set While the engine is programmed to start with the speed control feature activated you can opt to turn it off This means the engine s speed will fall as...

Страница 9: ...ode to return the engine to its normal condition even if the engine is kept without power for extended periods of time Reset to Factory Defaults To override the settings you currently have assigned to...

Страница 10: ...hours of operation or one year whichever comes first To access the gear box do the following 1 Remove the boiler shell 2 Remove the Phillips screws located on the front of the motor mounting plate 3...

Страница 11: ...of the truck frame Take note on which side the gears contact each other before disassembling Remove the screws the hold the side frames to the trucks 2 on the bottom 4 on top Remove the wheel axle ass...

Страница 12: ...remier Climax Logger Steam Engine Remove truck pivot screw Remove truckside mounting screws Remove truckside side frame Traction Tire Remove truckside mounting screw Figure 4 Replacing the Traction Ti...

Страница 13: ...included Do not overfill the unit or the fluid may leak out and coat the interior engine components If you choose not to add the fluid or have already added the fluid but choose to run smoke free tur...

Страница 14: ...ored and hard it should be replaced You can obtain replacement parts and wick replacement instructions from the M T H Parts Department Remove the two screws holding the lantern to the boiler front Uns...

Страница 15: ...nterior light bulb Gently but firmly pull bulb from the rubber grommet Replace the light and reassemble To replace the light in the lantern on the front of the engine first remove the boiler from its...

Страница 16: ...d Put the engine in neutral and leave the track voltage at 12 volts for 15 minutes If the garbled or distorted sounds are reduced the battery charge has run down and can be recharged Do this by leavin...

Страница 17: ...a separate bell button When I try to fire the coupler LYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled When I press the whistle button th...

Страница 18: ...engine is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2...

Страница 19: ...cycles through the LYS sequences LYS is programmed to start ringing the bell at that point After approximately 12 rings of the bell it will automatically turn off Because LYS must control various effe...

Страница 20: ...att Standard Lionel 1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Right Terminal Electronic Lionel LW A U 8 18v 75 Watt S...

Страница 21: ...ation rates Locomotive Lighting Control Independently controls locomotive headlights marker and interior lights and ditch lights Emergency Stop Single button push stops your trains but does not turn o...

Страница 22: ...ading operations Locomotive Consist Set up User can determine locomotive values for consist make ups allowing multiple locomotives belonging to a consist to operate together Query Locomotive Informati...

Страница 23: ...autions should be followed including the following Read this manual thoroughly before using this device M T H recommends that all users and persons supervising use examine the hobby transformer period...

Страница 24: ...tacting M T H for your Return Authorization number 3 Please make sure you have followed the instructions carefully before returning any merchandise for service Limited One Year Warranty All M T H prod...

Отзывы: