POU Install

Cooling & Hot Water Systems

Compressor uses R

134

a refrigerant.  

1.6

 ounces.

Cold water reservoir is manufactured from stainless steel.

Cold water temperature is preset at 

45

˚F range.  Adjustments can be made on rear 

of cooler (slotted screw.)  Turn clockwise for colder; counterclockwise for warmer 
(

¼

 turn at a time.)

Hot water tank is 1.2 liter stainless steel with a 

520

 watt heat band.  Temperature is 

controlled by non-adjustable thermostat/high limit switch.  Normal hot water temp 
is 

186

˚F +/- 

10

%.

i-Boil feature (almost boiling) water will dispense at a temperature of 

approximately 194˚F

.

Содержание Nexus CT

Страница 1: ...Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide 12152011 rev 12152011...

Страница 2: ...erne CA 91750 USA T 909 629 7301 F 909 629 7380 www mtnproducts com sales mtnproducts com POU Install Technical Specifications Height 43 5 Width 11 65 Depth 15 Weight 34 39 LBS Voltage 115VAC 60 HZ Cu...

Страница 3: ...water temperature in the hot tank temporarily to almost boiling when customers need hotter hot water for coffee and tea brewing soups noodles etc Accu Temp Proprietary dispensing system serves drinki...

Страница 4: ...y Unit to be used indoors only Ensure cooler is installed on a level floor Do not locate cooler in direct sunlight or next to a heat source Always maintain 4 of clearance around cooler for air circula...

Страница 5: ...Verne CA 91750 USA T 909 629 7301 F 909 629 7380 www mtnproducts com sales mtnproducts com POU Install Cooling Heating Capacities ARI Capacities 90 F Ambient Temp ARI Capacities 90 F Ambient Temp Cool...

Страница 6: ...d from stainless steel Cold water temperature is preset at 45 F range Adjustments can be made on rear of cooler slotted screw Turn clockwise for colder counterclockwise for warmer turn at a time Hot w...

Страница 7: ...e to select cold function Then press Water energizes cold water pump solenoid to dispense water The Water dispense button glows blue Stay Cool Cold water pump turns on for 5 seconds every 30 minutes t...

Страница 8: ...r about 3 seconds to select hot function Then press Water energizes hot water pump solenoid to dispense water The ring at the Water dispense button will glow red Approximately 15 seconds after releasi...

Страница 9: ...ong beep and the ring around Water button will flash Pink for an additional 2 minutes if water is drawn and the water temperature in the hot tank drops below 194 F the time will be shorter while the w...

Страница 10: ...CA 91750 USA T 909 629 7301 F 909 629 7380 www mtnproducts com sales mtnproducts com Reliably Serving a Thirsty World POU Install Light Brightness Control Current version has two brightness settings F...

Страница 11: ...7301 F 909 629 7380 www mtnproducts com sales mtnproducts com Reliably Serving a Thirsty World POU Install Filter Panel Access Accessed via the cup dispenser Unscrew the screw at the bottom of the cup...

Страница 12: ...POU Install Installation Follow the guidelines that the manufacturer provides for filter flushing Ensure installation complies with all local plumbing codes Inline shutoff valves should always be use...

Страница 13: ...y World POU Install Installation Continued Access for installation of filtration is gained by removing the cup dispenser Mounting is provided for bulkhead fittings for external filtration installation...

Страница 14: ...eliably Serving a Thirsty World POU Install Installation Continued Current float lid assembly is plumbed with tubing Connect this line to the outlet of the filter head Verify hot tank switch is in off...

Страница 15: ...hot tank Press and hold hot water button for about 3 seconds to unlock Press the dispense button and allow hot tank reservoir to fill with water Ensure all air has been purged from hot tank Repeat abo...

Страница 16: ...wo Modes 1 Auto clean SIP must be programmed at the initial time of cooler installation Refer to page 17 for programming instructions 2 Full clean mode User must place a vessel that can hold minimum 4...

Страница 17: ...p is heard approximately 7 seconds This will activate auto clean setup mode and white light on the Water dispense button will start to flash 2 Press the auto clean button X times 1 push of the button...

Страница 18: ...s completed at 12 noon entering setup mode and pushing auto clean button 12 times 1 push of the button equals 1 hour and then pressing the Water dispense button to lock in setting the cooler will star...

Страница 19: ...re will be a one second delay and the system will beep Y times IfY 6 check current time Example current time is 6 PM 6 beeps indicates the system will start at 12 AM If cooler looses power it will ret...

Страница 20: ...ull Clean Mode Place a vessel capable of holding 4 cups of water under the dispense nozzle Press the Manual Full Clean button white button located on the back of the cooler and hold for 3 seconds unti...

Страница 21: ...and Nexus FS will wait 30 minutes for possible ice bank in cold reservoir to melt When SIP is powered the cold water pump will run for approximately 10 seconds every 2 minutes to circulate ozonated wa...

Страница 22: ...filters are not blocked e Check to make sure solenoid and water pump are operating 2 Warm water dispensing from cold side a Verify usage is not exceeding GPH cooling capacity approx 1 GPH b Cooler set...