background image

RAPIDDOC

 LITE INSTALLATION GUIDE

5

 MTI P/N 063-00223 rev C ©2020 MTI All Rights Reserved

www.MTIGS.com  |  T:800.426.6844

2

1

4

3

6

5

Wall Mount Base Installation

Rotate the base cover clockwise until you feel the cover 
click and lock into place.

Place the Base Cover over the RapidDoc Base.

Attach the Wall Mount Base to the Mounting Plate.

Connect the RFID cable into the Wall Mount Base.

Connect the power supply cable into the Wall Mount 
Base. 

Line up the holes on the trim plate and the mounting 
plate with the holes on the gang box. Install using the 4 
long gang box screws included, with the cables coming 
out of the inner ring.

Ensure that this slot aligns with 

the manual unlock security screw 

in the base mount.

-CONTROLLED DOCUMENT-

063-00223

C-0

Status: Approved

ECO-111786

ECO-111786

Содержание RAPIDDOC LITE

Страница 1: ...pply RFID Access Card x5 included with RFID Reader only included with RFID Reader only RFID Authorization Card Hardware VESA Wall Mounting Plate Wall Trim Plate Wall Mount Base w AC Input Base Cover Red Handle Tool Security Screw x4 in Wall Mount Kit x8 in VESA Mount Kit CONTROLLED DOCUMENT 063 00223 C 0 Status Approved ECO 111786 ...

Страница 2: ...TI All Rights Reserved www MTIGS com T 800 426 6844 Dimensions Mounting Plate Wall Base Wall Mount Kit RFID Reader Optional 2 78 4 86 4 24 1 1 4 69 1 71 VESA Mount Kit RFID Reader Optional 9 25 48 Cable 3 5 CONTROLLED DOCUMENT 063 00223 C 0 Status Approved ECO 111786 ...

Страница 3: ...hose circled in blue for installation on a Double Gang Box 48 RFID Cable RapidDoc RapidDoc Determine the location of the RFID Reader within the 48 length of the RFID cable It is recommended to install the RapidDoc using a Gang Box attached to a wall stud Pull the charging cable from the power supply cable to the Gang box Install the RFID Flush Mount on the wall use anchor bolts if necessary CONTRO...

Страница 4: ...e Red Handle Tool where shown and turn it counter clockwise which will allow the module to rotate counter clockwise out of the mount Route the loose end of RFID cable from the RFID Module through the hole and the wall to the Gang box RFID Installation Pull the charging cable from the power supply and RFID cable out of the Gang Box It is recommended to use a Gang Box that is securely attached to a ...

Страница 5: ...e Attach the Wall Mount Base to the Mounting Plate Connect the RFID cable into the Wall Mount Base Connect the power supply cable into the Wall Mount Base Line up the holes on the trim plate and the mounting plate with the holes on the gang box Install using the 4 long gang box screws included with the cables coming out of the inner ring Ensure that this slot aligns with the manual unlock security...

Страница 6: ... you are using the VESA Bracket make sure you pull enough power supply cable out of the wall to reach the Wall Mount Base once it is attached to the VESA mount bracket VESA Base Installation Attach the Wall Mount Base to the Mounting Plate Place the Base Cover over the RapidDoc Base and rotate clockwise until you feel the cover click and it locks into place Ensure that this slot aligns with the ma...

Страница 7: ...FID Authorization Card on the RFID Module until the LED flashes IF AUTHORIZATION CARD IS LOST OR STOLEN CONTACT CUSTOMER SERVICE FOR REPLACEMENT 4 If no Access Card is detected the Base will return to normal condition waiting for registered Access Card to unlock the Base The Base can register a maximum of 20 Access cards The process will need to be repeated for each card If a 21st card is register...

Страница 8: ...istered The base can register a maximum of 20 Access cards Registering Access Cards NOTE The above grid is a conceptual visual representation of the Electronic Register ACCESS005 ACCESS004 ACCESS003 ACCESS002 ACCESS001 ACCESS005 ACCESS004 ACCESS003 ACCESS002 ACCESS001 ACCESS006 ACCESS005 ACCESS004 ACCESS002 ACCESS001 ACCESS006 ACCESS005 ACCESS004 ACCESS003 ACCESS002 IF AUTHORIZATION CARD IS LOST O...

Страница 9: ... will start Flashing Orange Wait until the flasing stops approximately 2 minutes and Try again If your tablet does not release try using the Red Handle Tool to manually remove the tablet RFID Release Within five seconds remove the case away from the base If the case is not removed within five seconds the lock will re engage Up to 10 access tries are allowed then a two minute waiting period before ...

Страница 10: ...k 10 times Remove the Tablet or it will be locked for 2 minutes Manual Release Use the other hand to remove the case while keeping the security screw turned Insert the Red Handle Tool into the security screw hole at the bottom of the RapidDoc base disk under the tablet Turn the Red Handle Tool clockwise until resistance is felt about halfway and hold Do not grab the tablet until after you twist th...

Страница 11: ...v C 2020 MTI All Rights Reserved www MTIGS com T 800 426 6844 Mounting Template Print this document at 100 or Actual Size to mark the drill holes for installing the RapidDoc RFID Flush Mount Plate CONTROLLED DOCUMENT 063 00223 C 0 Status Approved ECO 111786 ...

Страница 12: ...uraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution This device complies with Part 1...