![MTI FREEDOM CORE II Power Sensor Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/mti/freedom-core-ii-power-sensor/freedom-core-ii-power-sensor_product-manual_1852265010.webp)
FREEDOM CORE II
™ POWER/SCREAMER SENSOR
10
MTI P/N 063-00229 rev A ©2018 MTI All Rights Reserved
www.mobiletechinc.com | T:800.426.6844
LED TROUBLESHOOTING
Visual Reference
System Status
Condition
Solution
Sensor white double flash every
8 seconds
No audible alarm
Power is on, Sensor is disarmed
Mount customer product and
program/arm system
Sensor flashes red and white
Steady alarm
Sensor is in a state of alarm due
to theft, tampering or improperly
mounted customer product
Insert IntelliKey to silence alarm
Fix alarming condition (check
mounted product)
Remove IntelliKey
Sensor flashes red and white
No audible alarm
Sensor has been alarming for
more then 10 minutes.
Insert IntelliKey to silence alarm
Fix alarming condition (check
mounted product)
Remove IntelliKey
Sensor LED solid blue
No audible alarm
Short circuit in GeniusCable or
over current from the device
Replace GeniusCable
If issue is not resolved, the
device is too power hungry for
Freedom Core II system and
cannot be merchandised with it
Sensor LED off
Five double-beeps
System is in a state of battery
back-up mode
SYSTEM CANNOT BE
PROGRAMMED IN THIS STATE
Reconnect power
In order to maximize consumer shopping experience during open hours, consider the following steps to extend battery life:
• TURN OFF or put all displayed devices/SKUs in SLEEP mode for the off hours for your store.
• Lowering the brightness level (during open hours) on your devices by 15-20%
If you experience any condition not listed above, please contact Customer Service at 1-800-426-6844, Opt. 1
-CONTROLLED DOCUMENT-
063-00229
A-0
Status: Approved
ECO-106737
ECO-106737