INSTALLATION INSTRUCTIONS FOR AIR BATHS

!

 

!

  

Do not attempt to remove the foam or board from the bottom of the tub. Doing so may

        

cause damage and will void warranty.

 

1. Never handle the bath by the blower, piping or other equipment.
2. Make sure the manifold and airlines are protected when moving the tub into the house.
3. An access panel of at least 16” x 14” must be provided for the blower for any future servicing.
4. The blower must not be insulated and must have sufficient air space to permit proper

operation. Surrounding ambient air temperature should be between 72º F and 86º F.

5. The heating element on your blower heats the air blown into the tub to prevent the

water from cooling too quickly. It will not, under any circumstances, reheat or

maintain the temperature of the bath water.

6. The area underneath and around the tub must be cleaned thoroughly before finalizing

installation to prevent any particles from entering the blower or being blown into the air 

jets.

7. Before filling the tub, clean installation debris and dirt from the interior of the tub. If

necessary, use the soft brush attachment of a vacuum cleaner.

8. Fill tub and test for proper operation and leaks. Note: The blower must be plugged into

a GFCI protected outlet.

Note: All air baths are equipped with an automatic drying cycle. The blower will turn on for 1-2 minutes 

approximately 20 minutes after the air system is turned off. This drying cycle cannot be cancelled. Any 

attempt to cancel this cycle only resets the countdown timer. 

INSTALLATION INSTRUCTIONS FOR INTEGRAL SKIRTED TUBS

All MTI BASICS Integral Skirted tubs

 

include an integral molded front skirt

 and

 integral three-sided tile 

flange. These tubs are designed to be installed in a three-wall alcove.

1. Remove wooden blocks that may be attached to the bottom of the tub, then s

et

 tub into installation

location. 

Do NOT drag tub on floor! 

Level

 tub 

at the rim 

to

 

allow for proper drainage

 and mark studs at

the height indicating level

Provide proper support and maintain level of tub with use of 

Quik

r

ete, #1103

as a bedding compound.

 Plaster, sheet rock mud and sand are NOT acceptable

 

wet bedding

compounds 

and will void warranty!

2. A pre-leveled foam base comes standard on all MTI air baths and is optional for soaker and whirlpools

tubs. Pre-leveled foam base negates the need to wet bed on a flat and level surface.  Check the sub-

floor and tub for level before installing.  Quikrete may be used to even out any portion of the sub-floor

that is not flat or level.

3.

Carefully drill 1/8” holes through the tile flange at each 

pre-marked 

stud location. Secure to stud with

screws,

 

being careful not to over-tighten as this might cause the acrylic to crack or chip. Do not attempt

to drive

 

nails throught the integral flange. 

See image

s

 below.

Содержание BASICS MBCRFS6632

Страница 1: ...GUIDE Thank you for choosing an MTIS BASICS bath You have purchased a high quality acrylic bath hand crafted with pride in the USA We know it will give you many years of pleasure The instructions in...

Страница 2: ...hydrotherapy bath since medication may induce drowsiness affect heart rate blood pressure and circulation DANGER To reduce the risk of injury enter and exit the bath slowly WARNING Never operate elect...

Страница 3: ...ranty 12 13 Commercial Warranty 14 15 A T T E N T I O N I N S T A L L E R Access must be provided to each pump and or electrical component on your tub The access panel must have a minimum size of 16 x...

Страница 4: ...op of bowl K Inside bowl length at bottom of bowl L Flange edge depth M Top flange width N Drain center to edge of flange O Allow 1 2 to 1 to D for wet bedding P Pre leveled frame height Adds 1 2 3 to...

Страница 5: ...as ordered 6 If any leaks or operating problems are discovered do not complete installation until prob lems are resolved MTI will not be responsible for any costs involved with removing or reinstallin...

Страница 6: ...of the tub bottom It is recommended to use a plastic sheet barrier on top of and underneath the bedding compound Carefully lower tub into place Shift tub side to side to settle into compound The tub...

Страница 7: ...e Sand Mix to fill void between the bottom of the tub and floor If your tub was ordered with the pre leveled foam option no bedding compound is necessary Note If your floor is not completely level use...

Страница 8: ...c drying cycle The blower will turn on for 1 2 minutes approximately 20 minutes after the air system is turned off This drying cycle cannot be cancelled Any attempt to cancel this cycle only resets th...

Страница 9: ...your tub was ordered with the Virtual Spout tub filler the tub will fill through the small port on the inner wall of the tub Incoming water is connected to mixing valves mounted on the wall or a smal...

Страница 10: ...autions should always be followed including 1 All MTI BASICS whirlpool and air baths require a separate 15 amp 110VAC circuit for each pump or air system blower The inline heater for whirlpools adds 5...

Страница 11: ...necessary Q There is a leak at the pump when it s turned on How do we stop the leak A Check the rubber O rings for proper seating Tighten the large union nut rings on the pump These may have loosened...

Страница 12: ...ch as an old toothbrush gently brush around each non functioning jet Caution Do not turn the air system on while you have cleaning solution in the tub Drain and rinse tub Repeat if necessary Q Can I r...

Страница 13: ...the possibility of bacteria growth within the system 8 Bubble bath should only be used sparingly The action of the system will greatly increase the amount of bubbles The system must also be cleaned af...

Страница 14: ...ish remover Wintergreen oil dry cleaning solution lacquer thinners gasoline pine oil etc 4 Remove dust and dry dirt with a soft damp cloth 5 Clean grease oil paint or ink stains with isopropyl rubbing...

Страница 15: ...l or consequential damage loss of time inconvenience incidental expenses labor or material charges or any other costs related to the application of this warranty Warranty Limitations Your warranty is...

Страница 16: ...e unit properly allowing clear access for service Unit must be water tested prior to final enclosure Failure to do so will void warranty Damage occuring to the unit during installation is the responsi...

Страница 17: ...for this warranty to become effective Warranty Limitations Your warranty is void if unit is not water tested and inspected prior to final enclosure Our warranty does not cover defects damage or failur...

Страница 18: ...e unit properly allowing clear access for service Unit must be water tested prior to final enclosure Failure to do so will void warranty Damage occuring to the unit during installation is the responsi...

Страница 19: ...factured by MTI Baths Inc mtibaths com 670 N Price Road Sugar Hill GA 30518 800 783 8827 770 271 8228 Fax 800 438 8827 Copyright 2015 by MTI Baths Inc Modification Rights Reserved Part BASICSTUB rev 0...

Отзывы: