background image

20

Premier GP-9 Diesel Engine Operating Instructions

Transformer Compatibility and Wiring Chart

Proto-Sound 2.0 is designed to work with most standard AC transformers. 
The chart below lists the many compatible transformers.  Note that many of
the operational commands described in these instructions require a bell button, 
so if your transformer does not have its own bell button, you should consider
adding one to get the full benefit of the system.   In addition, the chart details
how the terminals on these transformers should be attached to your layout.  

Transformer

Model

Center Rail

Outside Rail

Min/Max.

Voltage

Power

Rating

Transformer

Type

Lionel 1032

U

A

5-16v

90-Watt

Standard

Lionel 1032M

U

A

5-16v

90-Watt

Standard

Lionel 1033

U

A

5-16v

90-Watt

Standard

Lionel 1043

U

A

5-16v

90-Watt

Standard

Lionel 1043M

U

A

5-16v

90-Watt

Standard

Lionel 1044

U

A

5-16v

90-Watt

Standard

Lionel 1053

U

A

8-17v

60-Watt

Standard

Lionel 1063

U

A

8-17v

60-Watt

Standard

All-Trol

Left Terminal

Right Terminal

0-24v

300-Watt

Electronic

Dallee Hostler

Left Terminal

Right Terminal

Electronic

Lionel LW

A

U

8-18v

75-Watt

Standard

Lionel KW

A or B

U

6-20v

190-Watt

Standard

Lionel MW

Outside Track

Terminal

Inside Track

Terminal

5-16v

50V.A.

Electronic

Lionel RS-1

Red Terminal

Black Terminal

0-18v

50V.A.

Electronic

Electronic

Lionel RW

U

A

9-19v

110-Watt

Standard

Lionel SW

U

A

Unknown

130-Watt

Standard

Lionel TW

U

A

8-18v

175-Watt

Standard

Lionel ZW

Lionel Post-War

Celebration 

Series ZW

A,B,C or D

A,B,C or D

U

Common

8-20v

0-20v

275-Watt

135/190 Watt

Standard

MTH Z-500

Red Terminal

Black Terminal

0-18v

50-Watt

Electronic

MTH Z-750

Red Terminal

Black Terminal

0-21v

75-Watt

Electronic

MTH Z-4000

Red Terminal

Black Terminal

0-22v

390-Watt

Electronic

* Conventional Mode Only

Содержание PREMIER GP-9 Diesel Engine

Страница 1: ...most other 3 rail locomotives rolling stock and accessories This locomotive is equipped with Proto Sound 2 0 with Digital Command System DCS This new system will allow you to operate your locomotive i...

Страница 2: ...FYS 7 Proto Coupler Operation 8 Speed Control 8 Lock into a Direction 9 Reset to Factory Defaults 9 Automatic Sounds 9 Maintenance 10 ProtoSmoke Unit Operation 10 Lubrication and Greasing Instruction...

Страница 3: ...in Fig 5 on pg 12 Do not over oil Use only a drop or two on each pivot point 2 Prime the operating smoke unit with smoke fluid before operating Add 15 20 drops of smoke fluid through the smokestack s...

Страница 4: ...n to turn it off Direction Your train is programmed to start in neutral To put the engine into forward and then to change the direction of the train or to put it into neutral firmly press and release...

Страница 5: ...2 0 features in order to prevent harm to yourself or your equipment Activating Proto Sound 2 0 Conventional Mode Features Proto Sound 2 0 features are activated by sequences of Bell and Whistle button...

Страница 6: ...FYS The reverse unit is temporarily disabled so that the train will not move as you use the Direction button to trigger the sounds and Proto Sound 2 0 has disabled operator control over the Whistle an...

Страница 7: ...stopped the engine to run the FYS Otherwise the engine without FYS will begin vibrating on the track as its motors strain to move the train since they cannot be automatically disabled during the FYS...

Страница 8: ...ed up and down grades and around curves much like an automobile cruise control You can add or drop cars on the run and the engine will maintain the speed you set While the engine is programmed to star...

Страница 9: ...he 1 horn 3 bells code to return the engine to its normal condition even if the engine is kept without power for extended periods of time Reset to Factory Defaults To override the settings you current...

Страница 10: ...ough the smokestack see Fig 2 We recommend M T H ProtoSmoke Seuthe LGB or LVTS fluids Do not overfill the unit or the fluid may leak out and coat the interior engine components If you choose not to ad...

Страница 11: ...fluid check the wick to see if it has become hard blackened and unabsorbent around the heating element Remove the smoke unit inspection cover from the smoke unit s body see Fig 4 After removing the ch...

Страница 12: ...comes first Follow the greasing instructions below Note that in some tightly packed engines you may need to move internal components temporarily in order to access the gears 1 To access the gear box...

Страница 13: ...rked with a G Periodically check the locomotive wheels and pickups for dirt and buildup which can cause poor electrical contact and traction as well as prematurely wear out the neoprene traction tires...

Страница 14: ...the grooved drive wheel See Fig 8 for which screws you must remove to do this Once the truck sides have been removed 1 Make sure the old tire has been completely removed from the groove in the drive w...

Страница 15: ...shell remove the shell and remove the wires from the wire clips Remove the light bulb and wires taking care to notice the path that the wires take on the inside of the shell Replace the bulb and reass...

Страница 16: ...at 12 volts for 15 minutes If the garbled or distorted sounds are reduced the battery charge has run down and can be recharged Do this by leaving the engine in neutral with track voltage at 12 volts f...

Страница 17: ...essing the button too quickly Try pressing the bell button more slowly taking approximately one full second to fully depress the button Reverse the transformer leads Check the wiring of the separate b...

Страница 18: ...als The engine is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto...

Страница 19: ...as the operator cycles through the FYS sequences FYS is programmed to start ringing the bell at that point After approximately 12 rings of the bell it will automatically turn off Because FYS must cont...

Страница 20: ...90 Watt Standard Lionel 1043M U A 5 16v 90 Watt Standard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Ri...

Страница 21: ...uts and matches smoke to locomotive speed Locomotive Lighting Control Controls locomotive headlights marker and interior lights beacon lights ditch lights and MARS lights Emergency Stop Single button...

Страница 22: ...motive values for consist make ups allowing multiple locomotives belonging to a consist to operate together Query Locomotive Information User can query locomotive programming to learn locomotive addre...

Страница 23: ...ty precautions should be followed including the following Read this manual thoroughly before using this device M T H recommends that all users and persons supervising use examine the hobby transformer...

Страница 24: ...acting M T H for your Return Authorization number 3 Please make sure you have followed the instructions carefully before returning any merchandise for service Limited One Year Warranty All M T H produ...

Отзывы: