Advanced Consisting
Advanced Consisting follows the NMRA standards. Any values
assigned to CV's 21-24 are ignored once the consist is removed
(CV19 set to 0).
?
Setting the MSB (Bit 7) of CV19 tells the engine that it is
facing reverse in the consist
?
Setting CV21 and CV22 determine which F Functions the
consist responds to
See diagram below for example
Custom Speed tables
Below is a table that shows the value to write to CV25 to achieve
the desired speed curve. For example, if you would like to use
speed curve 18 then:
1.
Write a value of 1 to CV52 to enable PWM Mode
2.
Write a value of 1 to bit 4 of Cv29
3.
Write a value of 18 to CV25. Your engine will now use the
speed curve #18 below
4.
If you want to create your own speed table using CV's 67-94
then write a value of 0 or 1 to Cv25
Premier 2-4-1A Mountain Steam Locomotive