background image

 

Stereo LINE inputs accept 0 dBV (1 V) line level signals from CD and DVD players, multimedia devices, MP3 
players, radio tuners, TV receivers, etc. 

Turntables CANNOT BE CONNECTED

 directly to the MZ54, as none of 

the inputs has a built-in RIAA preamplifier. 
 

4.2. Phantom power  

 

An internal 

jumper

 activates the 

Phantom

 power supply for all microphone inputs at a time, allowing to connect 

condenser microphones.  

 

5. OUTPUTS 
 
5.1. Zone outputs 

 

The MZ54 has four main or zone outputs, all balanced and with Euroblock connectors: ZONE 1, ZONE 2, ZONE 3 
and ZONE 4. 

 

Euroblock connector should be wired as indicated: 
 
Hot or direct signal  

 

Pin + 

Cold or inverted signal           

Pin - 

Ground  

 

 

Pin 

 

 

5.2. Phones output 
 

In the MONITOR section, the PHONES output allows to monitor any zone output signal, from 1 to 4, as well as the 
signal received through the fifth input of the equipment, dedicated to high-priority signals. 

 

6. CONSIDERATIONS AND START-UP 
 
6.1. Power-up 

 

This is done by means of the

 

Power switch (27).

  

 

6.2. Input gain 

 

The gain is controlled with knob (4)

 

for each input. 

 
The

 

SP indicator (2)

 

lights to indicate a signal presence in this input. 

 
The CLIP indicator (3)

 

warns that the channel is nearly overloaded. This indicator should never stay permanently 

lit. 
 
On the front panel, Input # 5 has a GAIN knob acting as a general control of this signal send to zone outputs in Priority 
mode (see 

4.2. Input 5, priority

). Additionally, inside the unit, 4 adjustment potentiometers allow to attenuate the 

individual signal sent from Input 5 to the 4 output zones, customising this input sound volume for the different zones in 
Priority mode.  
 

 

6.3. Destination selection for Input #5 

 

Next to the INPUT 5 gain knob on the front panel, use the ZONE 4 ways switch to define the destination zones for 
this input in Priority mode (see section 

4.2. Input 5, priority

). An output zone (from 1 to 4) is selected as Input #5 

destination when its switch is activated (downwards). 
 
If you want to work in Priority mode with activation by external contact closure, connect this external contact to PRIO 
terminals on the back panel.  
 

NOTE:

 Remember that with the other input #5 operating mode (Evacuation/Emergency), the ZONE selector for 

destination zones is deactivated, since this mode always mutes the current program signal in 

All

 zones outputs, 

replacing it with Input #5 signal. 

 

Содержание MZ54

Страница 1: ......

Страница 2: ...power 5 5 OUTPUTS 5 5 1 Zone outputs 5 5 2 Phones output 5 6 CONSIDERATIONS AND START UP 5 6 1 Power up 5 6 2 Input gain 5 6 3 Destination selection for Input 5 6 6 4 Equalization 6 6 5 Output volume adjustments 6 6 6 Wall remote control connection 6 6 7 Audio monitoring system 6 6 8 Security caps 6 7 FUNCTION LIST 7 8 FUNCTION DIAGRAM 8 9 TECHNICAL CHARACTERISTICS 9 10 BLOCK DIAGRAM 10 ...

Страница 3: ...one line levels the last two accepting line levels only 4 monophonic zone outputs with 2 band tone controls for each output adjustable with a screwdriver on front panel Switchable phantom power supply for microphone inputs Independent source selection and output volume adjustment per zone Connectivity with remote control panels for zone source selection and volume adjustment Local or remote zone c...

Страница 4: ...riority mode can be activated by automatic detection of a signal at the 5th input or by closure contact dry contact on the back panel Internal jumpers are used to select activation mode signal detection default or contact closure attenuation 20 30 default or 80 dB and recovery time 1 2 default or 3 seconds Emergency Evacuation mode Mutes the current program signal in All zone outputs and replaces ...

Страница 5: ...cator 2 lights to indicate a signal presence in this input The CLIP indicator 3 warns that the channel is nearly overloaded This indicator should never stay permanently lit On the front panel Input 5 has a GAIN knob acting as a general control of this signal send to zone outputs in Priority mode see 4 2 Input 5 priority Additionally inside the unit 4 adjustment potentiometers allow to attenuate th...

Страница 6: ...ection The wall remote controls are connected to the MZ54 by means of a standard CAT5 cable terminated on both ends with RJ 45 connectors insert one of them in a REMOTE port on the back panel ZONE 1 ZONE 2 ZONE 3 or ZONE 4 and the other in the RJ 45 port of the remote control RJ 45 connector wiring Pin 1 to Pin 1 White Orange GND Pin 2 to Pin 2 Orange REMOTE VOL 10V 0V MIN MAX Pin 3 to Pin 3 White...

Страница 7: ...ntrol for headphones output MONITOR 14 Headphones connector 15 Input sensitivity adjustment MIC LEVEL 16 Input selector MIC LINE 17 Signal input XLR3 connector 18 Signal input screw terminal LINE R 19 Signal input screw terminal MIC LINE L 20 Signal input screw terminal LINE L 21 Volume control LEVEL 22 Screw terminal FIRE LINK 23 Output screw terminal OUTPUT ZONE 24 RJ 45 connector REMOTE ZONE 25...

Страница 8: ...8 8 FUNCTION DIAGRAM ...

Страница 9: ...e Analog Control Frequency response LINE 5Hz 40kHz 3dB MIC BAL 5Hz 37kHz 3dB Harmonic distortion LINE 0 08 MIC BAL 0 1 CMRR MIC 70dB 1kHz Signal Noise ratio LINE 110dB MIC BAL 100dB Tone control BASS 100Hz 15dB TREBLE 10kHz 15dB Talkover TIME 1 2 3 sec EFFECT 20 30 80 dB Phantom voltage 18VDC Mains 90 264VCA 47 63Hz Power consumption 29VA Dimensions Panel 482 6x44mm Depth 195mm Weight 2 7kg Intern...

Страница 10: ...10 10 BLOCK DIAGRAM ...

Отзывы: