background image

 

1. IMPORTANT REMARK 

 

Thank you for choosing our MZ54. It is VERY IMPORTANT to carefully read this manual before any connection in 
order to maximize your use and get the best performance from this equipment. 
 
In order to guarantee the optimum operation of this unit, we strongly recommend that its maintenance be carried 
out by our Authorised Technical Services. 

 

1.1. Safety Precautions 
 

This apparatus must be earthed through its mains cable. 
Do not expose the unit to rain or water splashes, and do not place liquid containers or incandescent objects like 
candles on top of the unit. 
 

Any change in the configuration of the unit must be carried out by a qualified technician. Should any 
connection / disconnection task be done, always disconnect the unit from the mains supply. 
There are no user serviceable parts inside the unit. 

 

 
 

2. INTRODUCTION 

 

The MZ54 is a 5 input sources/4 zone outputs audio matrix especially designed for multi-zone sound system 
applications with independent source selection and volume adjustment. It also manages priority signals and 
messages for the diffusion of generic and/or evacuation warnings. 
 

 

Main characteristics: 

 
 

  4 stereo inputs (two of them accepting microphone/line levels, the last two accepting line levels only). 

  4 monophonic zone outputs, with 2-band tone controls for each output (adjustable with a screwdriver on front 

panel). 

  Switchable phantom power supply for microphone inputs. 

  Independent source selection and output volume adjustment (per zone). 

  Connectivity with remote control panels for zone source selection and volume adjustment. 

  Local or remote zone control mode selection (from the device front panel or from remote control panels). 

  Headphones monitoring section.  

  Euroblock connectors for inputs and outputs (input #1 has also a XLR type connector for MIC/LINE signal). 

  Removable front panel knobs with safety caps (included) to prevent unwanted access. 

 
3. INSTALLATION REQUIREMENTS 

 

The MZ54 has been especially designed to be installed in a standard 19" rack, taking up 1U. 
 
Since the MZ54 power consumption is very low, it doesn’t require forced ventilation. Nevertheless, you must avoid 
extreme temperature conditions and keep the atmosphere of the room in which it is located as dry and dust-free as 
possible. 
 
Keep the equipment far from noise sources (variable voltage regulators, motors, etc…) as well as from power 
cables. 

 

The MZ54 operates under voltages between 90 and 264 V at 47 to 63 Hz. This device features an over 
dimensioned power supply that adapts to the mains voltage in any country of the world with no need to make any 
adjustments. 
 

Содержание MZ54

Страница 1: ......

Страница 2: ...power 5 5 OUTPUTS 5 5 1 Zone outputs 5 5 2 Phones output 5 6 CONSIDERATIONS AND START UP 5 6 1 Power up 5 6 2 Input gain 5 6 3 Destination selection for Input 5 6 6 4 Equalization 6 6 5 Output volume adjustments 6 6 6 Wall remote control connection 6 6 7 Audio monitoring system 6 6 8 Security caps 6 7 FUNCTION LIST 7 8 FUNCTION DIAGRAM 8 9 TECHNICAL CHARACTERISTICS 9 10 BLOCK DIAGRAM 10 ...

Страница 3: ...one line levels the last two accepting line levels only 4 monophonic zone outputs with 2 band tone controls for each output adjustable with a screwdriver on front panel Switchable phantom power supply for microphone inputs Independent source selection and output volume adjustment per zone Connectivity with remote control panels for zone source selection and volume adjustment Local or remote zone c...

Страница 4: ...riority mode can be activated by automatic detection of a signal at the 5th input or by closure contact dry contact on the back panel Internal jumpers are used to select activation mode signal detection default or contact closure attenuation 20 30 default or 80 dB and recovery time 1 2 default or 3 seconds Emergency Evacuation mode Mutes the current program signal in All zone outputs and replaces ...

Страница 5: ...cator 2 lights to indicate a signal presence in this input The CLIP indicator 3 warns that the channel is nearly overloaded This indicator should never stay permanently lit On the front panel Input 5 has a GAIN knob acting as a general control of this signal send to zone outputs in Priority mode see 4 2 Input 5 priority Additionally inside the unit 4 adjustment potentiometers allow to attenuate th...

Страница 6: ...ection The wall remote controls are connected to the MZ54 by means of a standard CAT5 cable terminated on both ends with RJ 45 connectors insert one of them in a REMOTE port on the back panel ZONE 1 ZONE 2 ZONE 3 or ZONE 4 and the other in the RJ 45 port of the remote control RJ 45 connector wiring Pin 1 to Pin 1 White Orange GND Pin 2 to Pin 2 Orange REMOTE VOL 10V 0V MIN MAX Pin 3 to Pin 3 White...

Страница 7: ...ntrol for headphones output MONITOR 14 Headphones connector 15 Input sensitivity adjustment MIC LEVEL 16 Input selector MIC LINE 17 Signal input XLR3 connector 18 Signal input screw terminal LINE R 19 Signal input screw terminal MIC LINE L 20 Signal input screw terminal LINE L 21 Volume control LEVEL 22 Screw terminal FIRE LINK 23 Output screw terminal OUTPUT ZONE 24 RJ 45 connector REMOTE ZONE 25...

Страница 8: ...8 8 FUNCTION DIAGRAM ...

Страница 9: ...e Analog Control Frequency response LINE 5Hz 40kHz 3dB MIC BAL 5Hz 37kHz 3dB Harmonic distortion LINE 0 08 MIC BAL 0 1 CMRR MIC 70dB 1kHz Signal Noise ratio LINE 110dB MIC BAL 100dB Tone control BASS 100Hz 15dB TREBLE 10kHz 15dB Talkover TIME 1 2 3 sec EFFECT 20 30 80 dB Phantom voltage 18VDC Mains 90 264VCA 47 63Hz Power consumption 29VA Dimensions Panel 482 6x44mm Depth 195mm Weight 2 7kg Intern...

Страница 10: ...10 10 BLOCK DIAGRAM ...

Отзывы: