1244.6  1219.2  425.5 

390.5 

inches 

49 

48 

16.75  15.375 

 

 

Weight 

Kilograms  Pounds    

Capacities 

Water volume  Oil tank 

Shipping 

41 

91 

  

Liters 

102 

Operating  147 

324 

   US gallons 

27 

1.25 

 

The relationship between the flowing water level and the overflow weir is set by 

adjusting the outlet weir. The weir should be set so that when the water is flowing 

through the system, the water level upstream of the oil overflow weir is about 1/4” 

to 1/8” below the top of that weir. The weir is preset at the factory, but the 

elevation of the water level should be checked during the initial installation. It is 

not expected that it will be necessary to adjust the weir, unless operations 

change substantially. 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjust overflow weir by loosening bolts, sliding to desired elevation and re-

tightening bolts. Be sure weir is level. 

 

INITIAL INSTALLATION REQUIREMENTS AND SETUP 

 

The separator system must be provided with support to keep it level and elevated 

so that the water flow and oil flow out of the separator by gravity.   

 

The separator must be installed as level as possible. The system should be level 

within at least 1/8” end to end and side to side. 

 

Oil separation weir,  

Oil collection chamber and 

adjustable water overflow weir 

Содержание MSR-11 P

Страница 1: ...form of droplets of various sizes As the oil water mixture flows through the plates the oil droplets rise within the water due to their buoyancy As the droplets rise they come in contact with the und...

Страница 2: ...the plates The purpose of these plates is to enhance the coalescing of small droplets As the oil water mixture passes through the module small droplets are coalesced into larger ones which rise to the...

Страница 3: ...but the elevation of the water level should be checked during the initial installation It is not expected that it will be necessary to adjust the weir unless operations change substantially Adjust ov...

Страница 4: ...F THIS SEPARATOR OR FOR USE OUTSIDE THE PARAMETERS FOR WHICH IT IS DESIGNED INITIAL INSTALLATION REQUIREMENTS The separator must be installed as level as possible preferably within 1 8 per foot Excess...

Страница 5: ...hose piping and that adequate oil disposal facilities are provided Note Pump adjustment will be required if provided so it is advisable not to hard pipe the outlet water flow at this time Fill the se...

Страница 6: ...ns the solids may accumulate enough to plug the lower part of the module In this case efficiency will be reduced and hydrocarbons in the outlet water may exceed allowable limits 2 After approximately...

Страница 7: ...bove and reinstall Seal corrugated plate not installed or incorrectly installed Inspect for correct installation Install correctly Surfactants soaps and detergents in use upstream of separator Determi...

Отзывы: