11  Notes and General Information 

It  is  important  to  read  this  user  manual  thoroughly  and  clearly  understand  the  information  and  instructions.  The 

PolyGard

® 

transmitters  must  be  used  within  product  specification  capabilities.  The  appropriate  operating  and 

maintenance instructions and recommendations must be followed. 
Due  to  ongoing  product  development,  MSR  reserves  the  right  to  change  specifications  without  notice.  The 

information contained herein is based upon data considered to be accurate. However, no guarantee is expressed 

or implied regarding the accuracy of this data. 

11.1  Intended product application 

The  PolyGard

®

  CO  LC-1112  transmitters  are  designed  and  manufactured  for  control  applications  for  energy 

savings and OSHA air quality compliance in commercial buildings and manufacturing plants (i.e.,detection and 

automatic  exhaust  fan  control  for  automotive  maintenance  facilities,  enclosed  parking  garages,  engine  repair 

shops, warehouses with forklifts, fire stations, tunnels, etc.). 

11.2  Installers` responsibilities 

It  is  the  installer`s  responsibility  to  ensure  that  all  PolyGard

®

  transmitters  are  installed  in  compliance  with  all 

national  and  local  codes  and  OSHA  requirements.  Installation  should  be  implemented  only  by  individuals 

familiar with proper installation techniques and with codes, standards and proper safety procedures for control 

installations and the latest edition of the National Electrical Code (ANSI/NFPA70). It is also essential to strictly 

follow all instructions as provided in the user manual. 

11.3  Maintenance 

It  is  recommended  that  the  PolyGard

®

  transmitter  performance  check  is  done  on  a  routine  schedule.  Any 

performance deviations may be serviced based on needed requirements. Re-calibration and part replacement 

may be implemented in the field by a qualified individual and with the appropriate tools. Alternatively, the easily 

removable plug-in transmitter card with the sensor may be returned for service to IN

TEC

 Controls. 

11.4  Limited warranty 

MSR-Electronic-GmbH and IN

TEC

 Controls warrants the PolyGard

®

 transmitter for a period of two years, 

12 months normal exposure for the sensor, from the date of shipment against defects in material or workmanship. 

Should any evidence of defects in material or workmanship occur during the warranty period, IN

TEC

 Controls will 

repair or replace the product at their own discretion, without charge.
This warranty does not apply to units that have been altered, had attempted repair, or been subject to abuse, 

accidental or otherwise. The warranty also does not apply to units in which the sensor element has been 

overexposed or gas poisoned. The above warranty is in lieu of all other express warranties, obligations or liabilities.
This warranty applies only to the PolyGard

®

 transmitter. MSR-Electronic-GmbH and/or IN

TEC

 Controls shall 

not be liable for any incidental or consequential damages arising out of or related to the use of the PolyGard

®

 

transmitter.
If the PolyGard

®

 transmitter needs to be returned to IN

TEC

 Controls for service, an RMA number must be obtained 

prior to sending.

Specifications subject to change without notice. | USA 140916 | Page 13 of 13

12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN

TEC

 | relevantsolutions.com/inteccontrols

LC-1112_V3 – UserManual

Polygard® is a registered trademark of MSR | UMLC1112I01

Specifications subject to change without notice. | USA 160104 | Page 13 of 13

12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN

TEC

 | relevantsolutions.com/inteccontrols

LC-1112 V3 – UserManual

PolyGard

®

 is a registered trademark of MSR-Electronic GmbH | UMLC1112I01

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com

Specifications subject to change without notice. | UMLC1112I01 | USA 200211 | Page 13 of 13

LC-1112 V3 – UserManual

Содержание Intec Controls PolyGard CO LC-1112 V3

Страница 1: ...August 29 2006 Specifications subject to change without notice USA 140916 Page 1 of 13 12700 Stowe Drive Suite 100 Poway CA 92064 Ph 858 578 7887 888 GO INTEC relevantsolutions com inteccontrols LC 1...

Страница 2: ...oss sensitivity Data 9 9 Specifications 10 10 Wiring Configuration and Enclosure Dimensions 11 11 Notes and General Information 13 11 1 Intended product application 13 11 2 Installers responsibilities...

Страница 3: ...odes This signal is linear to the volume concentration of the sensed gas rather than the partial pressure The integrated two wire transformer converts this DC microampere signal to a standard 4 20 mA...

Страница 4: ...distribute several transmitters in a vertical and horizontal direction over the whole area to be monitored Avoid locations where water oil etc may influence proper operation and where mechanical dama...

Страница 5: ...minal strip X4 Connector 1 Power supply 24 VDC 17 28 VDC Connector 4 Signal 4 20 mA Connector 2 0 VDC DC common not needed 4 2 Wiring connection Unscrew cover of enclosure Unplug basic PCB from termin...

Страница 6: ...ttles 5 1 Calibration Zero adjustment Zero point calibration 4mA After sensor warm up Connect digital voltmeter to test pins and with a range selected that will display 2 VDC max Connect the calibrati...

Страница 7: ...ith a careful light turn Inspect the seating of the sensor element 5 2 Control span voltage calculation 160 mV x test gas concentration ppm 40 mV Measuring range CO ppm Example Measuring range CO conc...

Страница 8: ...se Unplug old sensor element out from the PCB Take new sensor element out of original packing Plug sensor element in the PCB Plug the PCB in terminal block X4 X5 carefully Calibrate after sensor warm...

Страница 9: ...20 ppm Hydrogen sulphide H2S 25 ppm 0 ppm Iso propanol C2H7OH 200 ppm 0 ppm Nitric oxide NO 50 ppm 8 ppm Nitrogen dioxide NO2 50 ppm 1 ppm Sulphur dioxide SO2 50 ppm 0 ppm Specifications subject to ch...

Страница 10: ...act GW Plast IEC 60695 2 12 GWFI 650 C fire retardant Enclosure color Light gray Protection NEMA12 IP 55 Installation Wall surface mounted or single gang electrical box Dimensions HxWxD 5 0 x 3 4 x 2...

Страница 11: ...COM1 X5 NC1 NO1 X6 P2 P1 Sensor 24 VDC_Inp 24VDC GND 24VDC OUT INP Bus_A Bus_B Calibration adapter Fig 4 Type CONKIT E CH LC Specifications subject to change without notice USA 140916 Page 11 of 13 1...

Страница 12: ...t to change without notice USA 140916 Page 12 of 13 12700 Stowe Drive Suite 100 Poway CA 92064 Ph 858 578 7887 888 GO INTEC relevantsolutions com inteccontrols LC 1112_V3 UserManual Polygard is a regi...

Страница 13: ...Any performance deviations may be serviced based on needed requirements Re calibration and part replacement may be implemented in the field by a qualified individual and with the appropriate tools Alt...

Отзывы: